Trench Technology
Katherm HK
Article no.:
143364211119M1
Overview
- KaControl MC control system for operation via separate touch panel TP 2"
- Room group control of up to ten units via factory-fitted CAN-bus (up to 100 m)
- Demand-led automatic or optional manual fan control
- Freely configurable multifunctional inputs that can be used, for example, to detect temperatures, window contacts, presence detectors, card readers etc.
- Integrated Webserver (Wi-Fi or LAN) for ease of commissioning, parametrisation, trend data analysis etc. on a laptop or mobile device
- Energy-saving, with flow-optimised impellers, cascaded arrangement as a continuous fan belt
- Easily removeable, plug & play fan
- Even air flow through convector
- Robust and whisper-quiet motor design
- Continuously variable control via external 0-10 V signal
- With anti-torsion device
- Made of the proven copper/aluminium combination, optimised for air flow and output
- Optionally available with projecting connections
- Painted graphite-grey
- Act as a finger guard for the tangential fan
- Filter frame, airflow baffle, grille seat and reinforcing stay to strengthen the trench
- Easy removal of tangential fan without tool
- Novl coupling/cone pin system
- Simultaneous sound decoupling
- For fast and safe wiring, saves installation time
Calculate performance data
Sound power octave spectrum
The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
Oktave Spektrum
EPD data
Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary
| A | B | C | D | |
|---|---|---|---|---|
| GWP - Total kg CO2 eq | 1.05E+02 | 9.29E+00 | 4.76E+00 | -5.48E+01 |
| GWP - fossil kg CO2 eq | 1.08E+02 | 8.30E+00 | 4.76E+00 | -5.42E+01 |
| GWP - Biogenic kg CO2 eq | -3.70E+00 | 9.69E-01 | 1.87E-03 | -2.64E-02 |
| GWP - Luluc kg CO2 eq | 7.58E-01 | 3.20E-02 | 2.33E-04 | -3.93E-01 |
| ODP kg CFC-11 eq | 8.31E-06 | 5.60E-07 | 9.36E-08 | -3.65E-06 |
| AP mol H+ eq | 1.34E+00 | 6.72E-02 | 1.94E-03 | -7.94E-01 |
| EP - fresh water kg P eq | 1.12E-01 | 5.71E-03 | 6.13E-05 | -6.59E-02 |
| EP - marine kg P eq | 1.33E-01 | 7.86E-03 | 6.56E-04 | -6.78E-02 |
| EP - country mol N eq | 1.47E+00 | 9.29E-02 | 7.53E-03 | -7.87E-01 |
| POCP kg NMVOC | 4.25E-01 | 2.32E-02 | 1.65E-03 | -2.28E-01 |
| ADPE kg Sb eq | 1.89E-02 | 1.90E-03 | 1.48E-06 | -1.51E-02 |
| ADPF MJ | 1.45E+03 | 2.05E+02 | 4.85E+00 | -6.68E+02 |
| WDP m³ depriv. | 4.69E+01 | 1.32E+00 | 1.49E-01 | -1.17E+01 |
| GWP-GHG kg CO2 eq | 1.06E+02 | 8.23E+00 | 4.76E+00 | -5.27E+01 |
| PM disease inc. | 7.10E-06 | 2.42E-07 | 2.95E-08 | -4.12E-06 |
| IR kBq U-235 eq | 1.03E+01 | 6.78E+00 | 2.82E-02 | -5.78E+00 |
| ETP - FW CTUe | 8.15E+03 | 4.52E+02 | 1.98E+01 | -5.81E+03 |
| HTP - C CTUh | 5.14E-07 | 1.58E-08 | 6.28E-10 | -3.09E-07 |
| HTP - NC CTUh | 1.25E-05 | 6.55E-07 | 1.01E-08 | -9.07E-06 |
| SQP - | 9.07E+02 | 9.08E+01 | 6.90E+00 | -3.18E+02 |
| PERE MJ | 3.40E+02 | 3.80E+01 | 1.58E-01 | -1.28E+02 |
| PERM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| PERT MJ | 3.40E+02 | 3.80E+01 | 1.58E-01 | -1.28E+02 |
| PENRE MJ | 1.45E+03 | 2.05E+02 | 4.85E+00 | -6.68E+02 |
| PENRM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| PENRT MJ | 1.45E+03 | 2.05E+02 | 4.85E+00 | -6.68E+02 |
| SM kg | 6.82E-02 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| RSF MJ | 4.63E-04 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| NRSF MJ | 2.97E-02 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| FW m³ | 9.77E-01 | 8.28E-02 | 6.10E-03 | -3.71E-01 |
| HWD kg | 3.61E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| NHWD kg | 8.99E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| RWD kg | 2.99E-03 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| CRU kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| MFR kg | 1.17E-03 | 0.00E+00 | 2.01E+01 | 0.00E+00 |
| MER kg | 5.13E-06 | 0.00E+00 | 1.59E+00 | 0.00E+00 |
| EE (Electrical) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| EE (Thermal) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Accessories
Control accessories KaControl MC
Touch Panel TP 2
Touch display with clear visualisations, black screen border and white case, 24 V, Room control unit for installation in a flush-mounted box with a freely selectable 55x55 mm frame, Protection class IP 20, made of Glass and PVC
Suitable for: All units with control configuration KaControl MC1 and MC2
Suitable for: All units with control configuration KaControl MC1 and MC2
Article no.:
196003311101
Modbus TCP licence ex-works
Licence for activation of the Modbus TCP interface ex-works, Hardware for use of the interface is installed and activated
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Article no.:
196003361103
Modbus RTU licence ex-works
Licence for activation of the Modbus RTU interface ex-works, Hardware for use of the interface is installed and activated
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Article no.:
196003361102
BACnet/IP licence ex-works
Licence for activation of the BACnet/IP interface ex-works, Hardware for use of the interface is installed and activated
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Article no.:
196003361104
KNX licence ex-works
Licence for activation of the KNX interface ex-works, Hardware for use of the interface is installed and activated
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Article no.:
196003361101
Surface-mounted housing
Complete with cover frame, Surface-mounted, Colour RAL 9010 gloss pure white, made of Thermoplastic, Type 3304111
Suitable for: Touch Panel TP 2
Suitable for: Touch Panel TP 2
Article no.:
196003304111
Surface-mounted housing
Complete with cover frame, Surface-mounted, Colour RAL 9005 matt satin deep black, made of Thermoplastic, Type 3304112
Suitable for: Touch Panel TP 2
Suitable for: Touch Panel TP 2
Article no.:
196003304112
room temperature sensor
to detect the room temperature., Surface-mounted, Protection class IP 20, Colour RAL 9010 pure white, made of Polycarbonat, Type 3321111
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Article no.:
196003321111
Valve kits
Differential pressure-independent valve kit
4-pipe, includes 2 differential pressure-independent axial valves, 2 return shut-off valves, angled and straight, 4 flexible stainless steel corrugated pipes, 1 elbow, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Suitable for: Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Article no.:
194001433540
Pre-settable valve kit
4-pipe, includes 2 pre-settable axial valves, 2 return shut-off valves, angled and straight, 4 flexible stainless steel corrugated pipes, 1 elbow, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm HK, max. Flow volume 920 l/h, DN 15
Suitable for: Katherm HK, max. Flow volume 920 l/h, DN 15
Article no.:
194001433740
Pre-settable valve kit
4-pipe, includes 2 pre-settable axial valves, 2 return shut-off valves, angled and straight, 4 flexible stainless steel corrugated pipes, 1 elbow, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm HK, max. Flow volume 260 l/h, DN 15
Suitable for: Katherm HK, max. Flow volume 260 l/h, DN 15
Article no.:
194001433140
Valve actuators, supplied loose
valve actuator
Drive T, 24 V AC/DC, 2-point, normally closed, 0.5m connecting line-MB2, PVC, VA10N, 1 W, Protection class III, Protection class IP 54 Cable length 0.12 m, supplied separately, made of Polyamide
Suitable for: All units with electro-mechanical control configuration KaControl MC1, KaControl C1 in conjunction with 2-way valve or differential pressure-independent valve
Suitable for: All units with electro-mechanical control configuration KaControl MC1, KaControl C1 in conjunction with 2-way valve or differential pressure-independent valve
Article no.:
196TS0P240500AB
Valves and return shut-off valves
Pre-settable thermostatic valve
Axial, pre-settable, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 260 l/h, DN 15
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 260 l/h, DN 15
Article no.:
194000346911
Pre-settable thermostatic valve
Axial, pre-settable, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 920 l/h, DN 15
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 920 l/h, DN 15
Article no.:
194000346914
Pre-setting key
Once per project necessary.
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Article no.:
194000346915
Pre-setting set
Once per project necessary.
Suitable for: pre-settable valve bodies and valve kits with higher flow from 250 l/h
Suitable for: pre-settable valve bodies and valve kits with higher flow from 250 l/h
Article no.:
194000346916
Return shut-off valve
2- and 4-pipe, Straight, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 610 l/h, DN 15
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 610 l/h, DN 15
Article no.:
194000145952
Return shut-off valve
2- and 4-pipe, angled, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 610 l/h, DN 15
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 610 l/h, DN 15
Article no.:
194000145953
Return shut-off valve
2- and 4-pipe, Straight, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 920 l/h, DN 15
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 920 l/h, DN 15
Article no.:
194000145954
Return shut-off valve
2- and 4-pipe, angled, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 920 l/h, DN 15
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 920 l/h, DN 15
Article no.:
194000145955
Differential pressure-independent thermostatic valve
Axial shape, differential pressure-dependent, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK or Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Suitable for: Katherm NK, Katherm QK or Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Article no.:
194000347914
Differential pressure-independent thermostatic valve
Straight, differential pressure-independent, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK or Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Suitable for: Katherm NK, Katherm QK or Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Article no.:
194000347913
Filter
Filter for air inlet
2- and 4-pipe, Replacement filter without frame, ISO Coarse 30% filter (G2)
Suitable for: Katherm HK 360, Length 1200 mm
Suitable for: Katherm HK 360, Length 1200 mm
Article no.:
143014321019
Condensate tray/pump
Connection kit for condensation pump
230 V 50 Hz, 20 W, Protection class II, supplied separately
Suitable for: Katherm HK or Katherm HK E, Width 320 mm and 360 mm
Suitable for: Katherm HK or Katherm HK E, Width 320 mm and 360 mm
Article no.:
194000143813
Connection kit for condensation pump
230 V 50 Hz, 20 W, Protection class II
Suitable for: Katherm HK or Katherm HK E, Width 320 mm and 360 mm
Suitable for: Katherm HK or Katherm HK E, Width 320 mm and 360 mm
Article no.:
194000143814
fitting kit for natural condensate drain
supplied separately
Suitable for: Katherm HK
Suitable for: Katherm HK
Article no.:
194000143817
fitting kit for natural condensate drain
factory-fitted
Suitable for: Katherm HK
Suitable for: Katherm HK
Article no.:
194000143818
Installation covers
Installation cover
to protect trench during installation, factory-fitted, grilles are packed separately
price per m
Suitable for: Katherm HK 360
price per m
Suitable for: Katherm HK 360
Article no.:
194000100360
Downloads
Declarations/Certificates
Certificate ISO 9001, 14001, 50001
PDF
(116 kB)
Digital EPD database Katherm HK E
Digital EPD database Katherm HK
EPD Katherm HK E
PDF
(1.6 MB)
EPD Katherm HK
PDF
(2.5 MB)
UKCA Declaration Katherm HK, QK, QK nano
PDF
(468 kB)
General product information
Products
PDF
(10.7 MB)
Information sheet trench heating BS EN 16430 UK version
PDF
(215 kB)
Manuals
KaControl MC - Multi Connect Climate Control Quick Start Guide
PDF
(1.3 MB)
Katherm HK 160/290, quick guide
PDF
(3.8 MB)
Katherm HK trench heating
PDF
(7.7 MB)
Technical catalogues
Katherm HK trench heating
PDF
(18 MB)
KaControl MC - Multi Connect
PDF
(2.2 MB)
Katherm HK trench heating
PDF
(13.1 MB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
CAD-Drawings
Katherm HK 360, 4-pipe, top view
PDF
(162 kB)
Katherm HK 360, 4-pipe, views
PDF
(147 kB)
Katherm HK 360, 4-pipe, top view
PDF
(162 kB)
Katherm HK 360, 4-pipe, views
DWG
(359 kB)
Katherm HK 360, 4-pipe, top view
DWG
(552 kB)
Installation plans
Katherm HK, KaControl MC version
PDF
(1.1 MB)