The product has been saved
to your wish list.
Click the symbol on the right on the 'products' button to access the wish list.

Katherm QK
Heating

Fan-assisted trench heating with EC technology.

Katherm QK
Your benefits:
  • Whisper-quiet EC technology

  • Optimised for use with low temperatures, outputs in accordance with DIN EN 16430

  • Made-to-measure

Key features

  • Short delivery times for our standard trenches
  • A matching edge profile for a perfect design with every grille
  • Quick installation with Eurokonus valve fittings, height-adjustment feet and raised floor mounting feet
  • Project solutions are available for all geometries with mitred corners, curved designs, column recesses or chamfered trenches
  • KaControl control system as standard or an electromechnical controller optional
  • Can be integrated into KaControl networks or building automation system, such as BACnet, Modbus or LON

 

Katherm QK - Your Energy Saving Calculator

 

  •  accessories Katherm module system:

 

 

TECHNOLOGY

  • Effective cold air screening of large windows
  • Extra long EC fan for uniform convector airflow resulting in high heat outputs at low sound emissions
  • Unique high-performance convector optimised for airflow and heat dissipation
  • Sturdy height adjustment feet with sound insulation for simple fixing of the trench and to avoid airborne sound transmission
  • Anti-twist device for the heating connection prevents damage to the convector when fitting the valves; valves optional as accessories
 

AREAS OF APPLICATION / INSTALLATION

  • Clear view and feel good temperature in front of full-length glass façades
  • For complete room heating, a supplementary heat supply and/or cold air screening
  • High-performance at low temperature ranges, perfect in combination with trend-setting heating systems
  • 120 different versions are available

... also good to know

  • The Katherm QK benefits from the expertise of our in-house Research and Development Center, tailored to customer requirements from the marketplace.
  • The heat outputs were measured and determined in accordance with E DIN EN 16430 "Fan-assisted radiators, convectors and trench convectors" Part 1: "Technical specifications and requirements" and Part 2: "Test method and rating of the heat output."
  • The QK standard lengths can be extended in 200 mm increments from 1000 mm to 3200 mm. Lengths that are not available can be created with individual tailor-made units.

Description

The combination of EC technology and KaControl stands for maximum energy efficiency, as the advantages of the EC fan can be ideally used in operation thanks to the continuous fan control by the KaControl technology.

 

At the same time, the air conditioning system that is operated at low fan speed to meet demand is advantageous especially in residential properties, offices and hotels. The ability to reduce the fan speed and thus also the air volume of the fans is of huge significance in terms of noise levels.

 

Kampmann Katherm QK with KaControl control are fully wired and delivered ex-works complete with all of their electrical components fitted. An effective parameterisable microprocessor provides all of the requisite functions, thus every Katherm QK has its own "intelligence" and can be operated in groups via Kampmann-t-Lan or CANbus networks.

 

KaControl Katherm QK can be fitted with plug-in communications interfaces for single room control or for connection to higher-order management systems. Every basic unit therefore has the potential to be integrated into a technical building automation network.

 

 

Functions

  • Valve actuation for 2- and 4-pipe systems
  • Temperature recording via KaController or external room sensor
  • Automatic continuous fan control according to room temperature
  • Maximum fan speed set via potentiometer on the PCB
  • Noiseless valve actuation via electronic relays
  • Motor fault evaluation, condensation alarm
  • Room frost protection function by monitoring of room temperature in every state to a limit value of 8°C
  • Frost protection function by fitting optional clip-on temperature sensor
  • Actuation by means of 0-10 V signal from an external BMS
  • Connection to open BMS system by optional interfaces (BACnet, Modbus)
   

System configuration

Control zones with up to 6 Katherm QK can be connected to a KaController via simple 2-wire bus connection.

 

Control zones with up to 30 Katherm QK can be connected to a KaController via a CANbus connection.

Technical catalogues
Katherm QK trench heatingdownload as.pdf, 3,47 MB
Leaflets/Flyers
Spezial Katherm QK trench heating , screen-optimizeddownload as.pdf, 1,25 MB
Spezial Katherm Modular System, screen-optimizeddownload as.pdf, 1,46 MB
Cross-product information
Product overview, products available in UKdownload as.pdf, 7,97 MB
Spezial Commercial buildingsdownload as.pdf, 2,17 MB
Spezial KaControl building automationdownload as.pdf, 794,90 KB
Spezial hoteldownload as.pdf, 2,41 MB
Information sheet trench heating - BS EN 16430, applicable in UKdownload as.pdf, 215,12 KB
Installation manuals
Katherm QKdownload as.pdf, 1,37 MB
Katherm QK with KaControldownload as.pdf, 4,02 MB
Katherm QK - Wiring Diagrams, electromechanical controldownload as.pdf, 1,22 MB
Katherm QK - Wiring Diagrams, Control KaControldownload as.pdf, 1,81 MB
Declarations/Certificates
Building product declaration Katherm trench heatingdownload as.pdf, 333,01 KB
Interseroh Recycling Certificatedownload as.pdf, 627,76 KB
TÜV Certificate ISO 9001:2008download as.pdf, 443,11 KB
UL Certificate of Compliancedownload as.pdf, 372,53 KB
EU Declaration of Conformity Katherm trench heatingdownload as.pdf, 1,09 MB
BIM data (Building Information Modeling)
BIM data download asDownload
CAD drawings
Katherm QK 182, connection right-hand, cross sections, viewsdownload as.dwg, 122,25 KB.dxf, 2,08 MB.pdf, 68,56 KB
Katherm QK 182, connection right-hand, top viewsdownload as.dwg, 682,16 KB.dxf, 8,09 MB.pdf, 166,87 KB
Katherm QK 182, cross sections, viewsdownload as.dwg, 113,75 KB.dxf, 1,98 MB.pdf, 67,19 KB
Katherm QK 182, top viewsdownload as.dwg, 647,22 KB.dxf, 8,05 MB.pdf, 168,38 KB
Katherm QK 207, connection right-hand, cross sections, viewsdownload as.dwg, 130,44 KB.dxf, 2,19 MB.pdf, 70,22 KB
Katherm QK 207, connection right-hand, top viewsdownload as.dwg, 612,99 KB.dxf, 7,96 MB.pdf, 170,46 KB
Katherm QK 207, cross sections, viewsdownload as.dwg, 127,06 KB.dxf, 2,08 MB.pdf, 68,55 KB
Katherm QK 207, top viewsdownload as.dwg, 638,54 KB.dxf, 8,17 MB.pdf, 174,61 KB
Katherm QK 207s, connection right-hand, cross sections, viewsdownload as.dwg, 124,97 KB.dxf, 2,18 MB.pdf, 69,52 KB
Katherm QK 207s, connection right-hand, top viewsdownload as.dwg, 613,43 KB.dxf, 7,95 MB.pdf, 172,89 KB
Katherm QK 207s, cross sections, viewsdownload as.dwg, 121,60 KB.dxf, 2,04 MB.pdf, 67,78 KB
Katherm QK 207s, top viewsdownload as.dwg, 634,97 KB.dxf, 8,03 MB.pdf, 168,31 KB
Katherm QK 232, connection right-hand, cross sections, viewsdownload as.dwg, 139,61 KB.dxf, 2,20 MB.pdf, 71,95 KB
Katherm QK 232, connection right-hand, top viewsdownload as.dwg, 636,13 KB.dxf, 8,21 MB.pdf, 181,21 KB
Katherm QK 232, cross sections, viewsdownload as.dwg, 133,08 KB.dxf, 2,20 MB.pdf, 70,08 KB
Katherm QK 232, top viewsdownload as.dwg, 696,15 KB.dxf, 8,14 MB.pdf, 173,35 KB
Katherm QK 232s, connection right-hand, cross sections, viewsdownload as.dwg, 130,32 KB.dxf, 2,11 MB.pdf, 69,88 KB
Katherm QK 232s, connection right-hand, top viewsdownload as.dwg, 719,15 KB.dxf, 8,54 MB.pdf, 173,23 KB
Katherm QK 232s, cross sections, viewsdownload as.dwg, 132,48 KB.dxf, 2,14 MB.pdf, 70,44 KB
Katherm QK 232s, top viewsdownload as.dwg, 705,16 KB.dxf, 8,30 MB.pdf, 171,34 KB
Technical details

This table only gives you a brief overview of the technical data. If you are looking for a more detailed product description and further technical data, please use the technical catalogue. The product configurator and the calculation program will help you to find the right article for your selection.


KaControl recirculating air control accessories

KaController 24 V, room control unit with one-touch operation, wall-mounted room control unit, with integral room temperature sensor; only for use with C1 controller

Installation instructions: i385_kurz_kacontroller_int.pdf

Download specifications (.rtf)
Article no.:
196003210001

KaController 24 V, room control unit with function buttons at the side, wall-mounted room control unit, with integral room temperature sensor; only for use with C1 controller, type 3210002

Installation instructions: i385_kurz_kacontroller_int.pdf

Download specifications (.rtf)
Article no.:
196003210002

KaControl room temperature sensor, wall-mounted, IP30, colour white RAL 9010, type 3250110

Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!
Download specifications (.rtf)
Article no.:
196003250110

KaControl outside sensor, wall-mounted, 50 x 65 x 45,5 mm, white similar to RAL 9010, IP54, type 3250112

Download specifications (.rtf)
Article no.:
196003250112

KaControl pipe clip-on sensor for recording the medium temperature, incl. clip-on strap, 3 m cable length, for changeover heating/cooling, type 03250115

Is there a risk of frost, e.g. due to the ingress of cold air – if so, then a KaControl clip-on pipe sensor should be chosen for each unit!
Download specifications (.rtf)
Article no.:
196003250115

KaControl CANBUS card, type 3260301

For increasing the number of units in a single-circuit system to a maximum of 30 units, one required per unit
For increasing the cable length from the first to the last unit from 30 to 500 m
Download specifications (.rtf)
Article no.:
196003260301

KaControl Building Management System

Serial Modbus card for connection to Modbus networks, type 3260101

Necessary for every secondary air unit!
Download specifications (.rtf)
Article no.:
196003260101

Valves and Return shut-off valves

Valve body, straight, 1/2" connection, type 146909

suitable for:
Katherm NK 182 (trench heights 150 mm and 200 mm)
Katherm NK 232/300/380 (all trench heights)
Katherm NX (trench heights 150 mm and 200 mm)
Katherm QK
Katherm HK 340
Download specifications (.rtf)
Article no.:
194000146909

Valve body, straight, 1/2" connection, pre-settable, type 346909

suitable for:
Katherm NK 182 (trench heights 150 mm and 200 mm)
Katherm NK 232/300/380 (all trench heights)
Katherm NX (trench heights 150 mm and 200 mm)
Katherm QK
Katherm HK 340
Download specifications (.rtf)
Article no.:
194000346909

Pre-setting key, type 346915

Pre-setting key for valve bodies type 346909, 346910, 346911 and convector valve set type 126103, pre-settable, one required per project
Download specifications (.rtf)
Article no.:
194000346915

Return shut-off valve, 1/2" connection, straight, type 145952

suitable for:
Katherm NK, Katherm NX,
Katherm QK, Katherm QX,
Katherm HK 320, Katherm HK 340
Download specifications (.rtf)
Article no.:
194000145952

Valve Actuators

Thermoelectric actuator, 24 V, type 146906

Download specifications (.rtf)
Article no.:
194000146906

Thermostats

Room thermostat with speed setting in a flat surface-mounted housing, colour white, with thermal feedback. Setting of the room temperature and pre-setting of the speed via turning knobs, type 342924

Room thermostat for infinitely adjustable parallel control of:
- max. 10 Katherm QK
- max. 10 Katherm QK nano
- max. 5 Katherm QX (up to a length of 1900 mm) or 3 Katherm QX (from a length of 2100 mm)
Download specifications (.rtf)
Article no.:
194000342924

Surcharge for mitres

Surcharge for mitres, with 90° roll-up grille

Download specifications (.rtf)
Article no.:
194000142518

Surcharge for mitres, with roll-up grille, other angles

Download specifications (.rtf)
Article no.:
194000142618

Surcharge for mitres, with 90° linear grille

Download specifications (.rtf)
Article no.:
194000142718

Surcharge for mitres, with linear grille, other angles

Download specifications (.rtf)
Article no.:
194000142818

Installation covers

Wooden installation cover to protect trench during installation, factory-fitted, grilles are packed separately

Download specifications (.rtf)
Article no.:
194000100918


What are the energy-savings with the EC motors used in Katherm QK?

A higher degree of motor efficiency is possible with the new highly efficient EC fans that are capable of achieving energy-savings of up to 60% compared with conventional split-pole motors. 

How many Katherm QK can be controlled with one KaControl unit?

Up to 6 Katherm QK can be controlled via the KaControl T-LAN interface, depending on the control and regulation concept. This can be extended up to 30 Katherm QK via a CANbus interface (CANbus card needed). 

Which models are available?

The following Katherm QK are available:

 

  • 3 trench widths 182, 207 and 232 mm with 2 additional output ranges. (These are available on request).
  • 1 trench height 112 mm
  • 12 trench lengths from 1000 to 3200 mm in 200 mm increments
  • 8 grille colours as roll-up or linear grilles
  • KaControl control system as standard or an optional electromechanical controller