Trench Technology
Katherm HK
Article no.:
14332231143500
Overview
- All the installed components are centrally arranged on a terminal block
- Electric connection unit is positioned for ease of access
- Built-in 230 V/24 V power supply unit
- Control by Kampmann room thermostats or on-site controls
- Option to wire through to the next unit
Katherm HK units with supply air function are perfectly suited to supply primary air (fresh air) into a space, seamlessly combining heating, cooling and a supply of fresh air. There are two versions available: primary air intake via supply air modules or through supply air trenches. In both versions, the primary air volume flow exits the trench at a minimal and low-turbulence air discharge speed. The volume of air supplied can be adjusted as required by means of air sliders.
- Energy-saving, with flow-optimised impellers, cascaded arrangement as a continuous fan belt
- Easily removeable, plug & play fan
- Even air flow through convector
- Robust and whisper-quiet motor design
- Continuously variable control via external 0-10 V signal
- With anti-torsion device
- Made of the proven copper/aluminium combination, optimised for air flow and output
- Optionally available with projecting connections
- Painted graphite-grey
- Act as a finger guard for the tangential fan, filter frame, airflow baffle, grille seat and reinforcing stay to strengthen the trench
- In a 2-pipe version for additional electric heating
- With integral, continuously variably controllable electric heating coil
- With built-in safety chain consisting of 2 safety temperature switches
- Sustainable 4-pipe system solution at the cost of a 2-pipe system
- Easy removal of tangential fan without tool
- Novl coupling/cone pin system
- Simultaneous sound decoupling
- For fast and safe wiring, saves installation time
Accessories
Control accessories electromechanical 230 V
Room thermostat
Heating/Cooling, 2- and 4-pipe, 3-stage. Only in conjunction with valves/valve kits with actuator, with OFF/Manual/Automatic fan switchover, 230 V AC, Open/Closed, Surface-mounted, Protection class II, Protection class IP 30, Temperature setting range 5 - 30 °C, Colour similar to RAL 9010 pure white, Type 30155
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units electromechanical, 5 Katherm HK Trench Technology, 5 TOP, Ultra or Ultra Allround Unit Heaters, 5 Venkon or PowerKon LT Fan Coils, 5 KaCool D AF, KaCool W or KaDeck Fan Coils
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units electromechanical, 5 Katherm HK Trench Technology, 5 TOP, Ultra or Ultra Allround Unit Heaters, 5 Venkon or PowerKon LT Fan Coils, 5 KaCool D AF, KaCool W or KaDeck Fan Coils
Article no.:
196000030155
Climate Controller
Heating/Cooling, 2- and 4-pipe, without Modbus, only with valves/valve kits Open/Closed, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9010 pure white, Type 148941
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.:
196000148941
Climate Controller
Heating/Cooling, 2- and 4-pipe, without Modbus, only with valves/valve kits Open/Closed, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9004 signal black, Type 148942
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.:
196000148942
Climate Controller
Heating/Cooling, 2- and 4-pipe, with Modbus, only with valves/valve kits Open/Closed, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9010 pure white, Type 148943
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.:
196000148943
Climate Controller
Heating/Cooling, 2- and 4-pipe, with Modbus, only with valves/valve kits Open/Closed, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9004 signal black, Type 148944
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.:
196000148944
Valve kits
Differential pressure-independent valve kit
Connection 1/2'' Max. operating pressure 10 bar, supplied separately
Suitable for: Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Suitable for: Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Article no.:
194001433520
Differential pressure-independent valve kit
Connection 1/2'' Max. operating pressure 10 bar, factory-fitted
Suitable for: Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Suitable for: Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Article no.:
194001434520
Pre-adjustable valve kit
Connection 1/2'' Max. operating pressure 10 bar, supplied separately
Suitable for: max. Flow volume 920 l/h, DN 15
Suitable for: max. Flow volume 920 l/h, DN 15
Article no.:
194001433720
Pre-adjustable valve kit
Connection 1/2'' Max. operating pressure 10 bar, factory-fitted
Suitable for: max. Flow volume 920 l/h, DN 15
Suitable for: max. Flow volume 920 l/h, DN 15
Article no.:
194001434720
Pre-adjustable valve kit
2-pipe, Connection 1/2''
Suitable for: Katherm HK
Suitable for: Katherm HK
Article no.:
194001433120
Pre-adjustable valve kit
Connection 1/2'' Max. operating pressure 10 bar, factory-fitted
Suitable for: max. Flow volume 260 l/h, DN 15
Suitable for: max. Flow volume 260 l/h, DN 15
Article no.:
194001434120
Valve actuator kits
Valve actuator kit
Drive T, 230 V AC, 2-point, normally closed, 0,5m Anschlussleitung-AEH, PVC, VA10N, 1 W, Protection class II, Protection class IP 54, Cable length 0.12 m, supplied separately, made of Polyamide
Article no.:
1960TS0P02050010B
Valve actuator kit
Drive T, 230 V AC, 2-point, normally closed, 0,5m Anschlussleitung-AEH, PVC, VA10N, 1 W, Protection class II, Protection class IP 54, Cable length 0.12 m, factory-fitted, made of Polyamide
Article no.:
1960TS0P02050010M
Valves and return shut-off valves
Valve body
Axial, pre-settable, Connection 1/2'' kvs value 1 m³/h, Max. operating pressure 10 bar
Suitable for: Katherm NK 137/182 (trench heights 92 mm and 120 mm), Katherm HK, DN 15
Suitable for: Katherm NK 137/182 (trench heights 92 mm and 120 mm), Katherm HK, DN 15
Article no.:
194000346911
Valve body
Axial, pre-settable, Connection 1/2'' kvs value 2.65 m³/h, Max. operating pressure 16 bar
Suitable for: for higher flow from 250 l/h, DN 15
Suitable for: for higher flow from 250 l/h, DN 15
Article no.:
194000346914
Pre-setting key
Once per project necessary.
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Article no.:
194000346915
Pre-setting set
Suitable for: pre-settable valve bodies and valve kits with higher flow from 250 l/h
Article no.:
194000346916
Return shut-off valve
Straight, Connection 1/2''
Suitable for: Katherm NK, Katherm QK or Katherm HK
Suitable for: Katherm NK, Katherm QK or Katherm HK
Article no.:
194000145952
Return shut-off valve
angled, Connection 1/2''
Suitable for: Katherm HK
Suitable for: Katherm HK
Article no.:
194000145953
Return shut-off valve
Straight, Connection 1/2''
Suitable for: for higher flow from 250 l/h
Suitable for: for higher flow from 250 l/h
Article no.:
194000145954
Return shut-off valve
angled, Connection 1/2''
Suitable for: for higher flow from 250 l/h
Suitable for: for higher flow from 250 l/h
Article no.:
194000145955
Filter
Filter for air inlet
Replacement filter without frame, ISO Coarse 30% filter (G2)
Suitable for: Katherm HK, Length 2000 mm
Suitable for: Katherm HK, Length 2000 mm
Article no.:
143014313035
Condensate tray/pump
Connection kit for condensation pump
230 V 50 Hz, 20 W, supplied separately, Type 143813
Suitable for: width 320 mm, height 130 mm and width 360 mm, height 210 mm, Katherm HK
Suitable for: width 320 mm, height 130 mm and width 360 mm, height 210 mm, Katherm HK
Article no.:
194000143813
Connection kit for condensation pump
230 V 50 Hz, 20 W, factory-fitted, Type 143814
Suitable for: width 320 mm, height 130 mm and width 360 mm, height 210 mm, Katherm HK
Suitable for: width 320 mm, height 130 mm and width 360 mm, height 210 mm, Katherm HK
Article no.:
194000143814
Installation covers
Installation cover
to protect trench during installation, factory-fitted, grilles are packed separately
price per m
Suitable for: Katherm HK
price per m
Suitable for: Katherm HK
Article no.:
194000100320
Downloads
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(194 kB)
Certificate ISO 9001:2008
PDF
(118 kB)
Digital EPD database Katherm HK E
Digital EPD database Katherm HK
EPD Katherm HK E
PDF
(1.6 MB)
EPD Katherm HK
PDF
(2.5 MB)
UKCA Declaration Katherm HK, QK, QK nano
PDF
(468 kB)
Cross-product information
Products
PDF
(10.7 MB)
Information sheet trench heating BS EN 16430 UK version
PDF
(215 kB)
Manuals
KaControl for Airblock KG
PDF
(34.1 MB)
Katherm HK trench heating
PDF
(7.7 MB)
Katherm HK, brief instructions
PDF
(3.8 MB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
Technical catalogues
Katherm HK trench heating
PDF
(13.1 MB)
CAD-Drawings
Katherm HK, trench width 320 mm, 2-pipe system, views
PDF
(122 kB)
Katherm HK, trench width 320 mm, 2-pipe system, top views
PDF
(145 kB)
Katherm HK, trench width 320 mm, 2-pipe system, views
DWG
(263 kB)
Katherm HK, trench width 320 mm, 2-pipe system, views
DXF
(1.9 MB)
Katherm HK, trench width 320 mm, 2-pipe system, top views
DWG
(535 kB)
Katherm HK, trench width 320 mm, 2-pipe system, top views
DXF