Fan Coils
KaCool D HY
Article no.:
32700824407100
Overview
- Outlet optimised for maximum comfort through side air outlet and utilisation of the Coanda effect
- Provides easy access to maintenance components
- Hygiene-certified in line with VDI 6022
- Certified by the HyBeta Hygiene Institute
- High-performance copper-aluminium heat exchanger
- With high heat and cooling outputs
- Optimised in terms of air flow
- Continuously variable EC single-phase radial fan
- Excellent efficiency through the use of EC technology
- Compact design due to external rotor motor technology
- Quiet operation due to optimised air flow guidance
Different valve kits are available: 2-way, 3-way and differential pressure-independent valves combined with corrugated pipes and actuators
- For CHW, LPHW and condensate drainage
- Drip tray is supplied with the unit
Calculate performance data
Sound power octave spectrum
The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
Oktave Spektrum
Accessories
Control accessories electromechanical 230 V
Room thermostat
Heating/Cooling, 2- and 4-pipe, 3-stage. Only in conjunction with valves/valve kits with actuator, with OFF/Manual/Automatic fan switchover, 230 V AC, Open/Closed, Surface-mounted, Protection class II, Protection class IP 30, Temperature setting range 5 - 30 °C, Colour similar to RAL 9010 pure white, Type 30155
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units electromechanical, 5 Katherm HK Trench Technology, 5 TOP, Ultra or Ultra Allround Unit Heaters, 5 Venkon or PowerKon LT Fan Coils, 5 KaCool D AF, KaCool W or KaDeck Fan Coils
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units electromechanical, 5 Katherm HK Trench Technology, 5 TOP, Ultra or Ultra Allround Unit Heaters, 5 Venkon or PowerKon LT Fan Coils, 5 KaCool D AF, KaCool W or KaDeck Fan Coils
Article no.:
196000030155
Clock thermostat
Heating/Cooling, 2- and 4-pipe, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, 1 W, flush-mounted, Protection class II, Protection class IP 30, Colour similar to RAL 9010 pure white, Type 30256
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units electromechanical, 5 TOP, Ultra or Ultra Allround Unit Heaters, 5 Venkon Fan Coils, 5 KaCool D AF, KaCool W or KaDeck Fan Coils
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units electromechanical, 5 TOP, Ultra or Ultra Allround Unit Heaters, 5 Venkon Fan Coils, 5 KaCool D AF, KaCool W or KaDeck Fan Coils
Article no.:
196000030256
Climate Controller
Heating/Cooling, 2- and 4-pipe, without Modbus, only with valves/valve kits Open/Closed, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9010 pure white, Type 148941
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.:
196000148941
Climate Controller
Heating/Cooling, 2- and 4-pipe, without Modbus, only with valves/valve kits Open/Closed, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9004 signal black, Type 148942
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.:
196000148942
Climate Controller
Heating/Cooling, 2- and 4-pipe, with Modbus, only with valves/valve kits Open/Closed, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9010 pure white, Type 148943
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.:
196000148943
Climate Controller
Heating/Cooling, 2- and 4-pipe, with Modbus, only with valves/valve kits Open/Closed, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9004 signal black, Type 148944
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.:
196000148944
Valve kits
2-way valve kit
4-pipe, 2-way valve, 2 St. 230 V 2-point actuator 230 V Open/Close, thermoelectric, 50 Hz, 1.8 W, Connection 1/2'' with external thread, kvs value 1.7 m³/h, water with glycol <50%, supplied separately
Suitable for: Model size 1 - 4
Suitable for: Model size 1 - 4
Article no.:
325009014110
3-way valve kit
4-pipe, 3-way valve, 2 St. 230 V 2-point actuator 230 V Open/Close, thermoelectric, 50 Hz, Connection 1/2'' with external thread, kvs value 1.7 m³/h, water with glycol <50%, supplied separately
Suitable for: Model size 1 - 4
Suitable for: Model size 1 - 4
Article no.:
325009014120
Differential pressure-independent valve kit
4-pipe, 230 V 2-point actuator 230 V Open/Close, 50 Hz, Connection 1/2'' water with glycol <50%, supplied separately
Suitable for: Model size 2 - 4, Min. Flow volume 150 l/h, max. Flow volume 1050 l/h, DN 15
Suitable for: Model size 2 - 4, Min. Flow volume 150 l/h, max. Flow volume 1050 l/h, DN 15
Article no.:
325009024310
Condensate tray/pump
condensate pump set
condensate pump for cooling below the dew point to discharge any condensate produced, 100 V240 V AC, 50 - 60 Hz, consisting of condensate pump, retaining panel, connecting bracket, screws and condensate pump accessories, 12 W, Protection class IP 44, supplied separately
Suitable for: KaCool D HY Fan Coils
Suitable for: KaCool D HY Fan Coils
Article no.:
327007000400
Additional colours
surcharge for RAL colour of your choice
Price per panel.
Suitable for: Model size 1 - 4, RAL 9016 metal panel, KaCool D AF or KaCool D HY Fan Coils
Suitable for: Model size 1 - 4, RAL 9016 metal panel, KaCool D AF or KaCool D HY Fan Coils
Article no.:
325008000101
Downloads
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(194 kB)
Certificate ISO 9001:2008
PDF
(118 kB)
Prüfzertifikat KaCool D HY
PDF
(141 kB)
Cross-product information
Products
PDF
(10.7 MB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
CAD-Drawings
Fan Coil KaCool D HY, Baugroesse 1 - 4, PDF
PDF
(274 kB)
Fan Coil KaCool D HY, Baugroesse 1 - 4, DWG
DWG
(567 kB)
Manuals
Montageanleitung KaCool D HY
PDF
(16.3 MB)