Trench Technology
Katherm QK
Article no.:
142411111415M1
Overview
- KaControl MC control system for operation via separate touch panel TP 2"
- Room group control of up to ten units via factory-fitted CAN-bus (up to 100 m)
- Demand-led automatic or optional manual fan control
- Freely configurable multifunctional inputs that can be used, for example, to detect temperatures, window contacts, presence detectors, card readers etc.
- Integrated Webserver (Wi-Fi or LAN) for ease of commissioning, parametrisation, trend data analysis etc. on a laptop or mobile device
The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.
- For fast connection
- Saves installation time
- Optional valves (accessories)
- For quick and safe electrical connection
- Saves installation time
- For control options: KaControl, -C1 and 230 V electromechanical --00
- Including 230/24 V power unit
- Removable end panel for ease of connection of trenches
- As visual cover and protection against dirt ingress
- A proven combination of copper/aluminium
- Optimised for air flow and heat dissipation
- Painted graphite-grey
Treated supply air can also be fed into the rooms through the Katherm supply air module (Length 400 mm).
Calculate performance data
Sound power octave spectrum
The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
Oktave Spektrum
EPD data
Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary
A | B | C | D | |
---|---|---|---|---|
GWP - Total kg CO2 eq | 2.51E+01 | 2.04E+00 | 8.36E-01 | -1.00E+01 |
GWP - fossil kg CO2 eq | 2.53E+01 | 1.84E+00 | 8.36E-01 | -9.91E+00 |
GWP - Biogenic kg CO2 eq | -5.47E-01 | 1.99E-01 | 3.34E-04 | -7.58E-03 |
GWP - Luluc kg CO2 eq | 3.24E-01 | 1.00E-02 | 4.34E-05 | -8.20E-02 |
ODP kg CFC-11 eq | 2.16E-06 | 1.29E-07 | 1.72E-08 | -6.96E-07 |
AP mol H+ eq | 2.38E-01 | 1.47E-02 | 3.50E-04 | -1.20E-01 |
EP - fresh water kg P eq | 2.05E-02 | 1.02E-03 | 1.13E-05 | -1.02E-02 |
EP - marine kg P eq | 4.83E-02 | 3.90E-03 | 1.19E-04 | -1.12E-02 |
EP - country mol N eq | 2.91E-01 | 2.06E-02 | 1.25E-03 | -1.28E-01 |
POCP kg NMVOC | 8.60E-02 | 4.95E-03 | 2.99E-04 | -3.79E-02 |
ADPE kg Sb eq | 2.71E-03 | 2.18E-04 | 2.75E-07 | -1.93E-03 |
ADPF MJ | 3.48E+02 | 4.42E+01 | 8.69E-01 | -1.24E+02 |
WDP m³ depriv. | 6.01E+00 | 3.08E-01 | 2.63E-02 | -1.75E+00 |
GWP-GHG kg CO2 eq | 2.49E+01 | 1.82E+00 | 8.36E-01 | -9.62E+00 |
PM disease inc. | 1.81E-06 | 5.65E-08 | 5.38E-09 | -7.16E-07 |
IR kBq U-235 eq | 4.55E+00 | 1.48E+00 | 5.08E-03 | -1.15E+00 |
ETP - FW CTUe | 1.45E+03 | 1.03E+02 | 3.62E+00 | -8.45E+02 |
HTP - C CTUh | 1.14E-07 | 3.21E-09 | 1.33E-10 | -5.21E-08 |
HTP - NC CTUh | 2.19E-06 | 1.37E-07 | 1.90E-09 | -1.30E-06 |
SQP - | 1.85E+02 | 2.16E+01 | 1.23E+00 | -4.83E+01 |
PERE MJ | 9.91E+01 | 8.46E+00 | 2.95E-02 | -2.50E+01 |
PERM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT MJ | 9.91E+01 | 8.46E+00 | 2.95E-02 | -2.50E+01 |
PENRE MJ | 3.48E+02 | 4.42E+01 | 8.69E-01 | -1.24E+02 |
PENRM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT MJ | 3.48E+02 | 4.42E+01 | 8.69E-01 | -1.24E+02 |
SM kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW m³ | 1.72E-01 | 1.96E-02 | 8.41E-04 | -6.16E-02 |
HWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD kg | 1.19E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR kg | 0.00E+00 | 0.00E+00 | 3.62E+00 | 0.00E+00 |
MER kg | 0.00E+00 | 0.00E+00 | 2.96E-01 | 0.00E+00 |
EE (Electrical) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Accessories
Control accessories KaControl MC
Touch Panel TP 2
Touch display with clear visualisations, 24 V, Room control unit for installation in a flush-mounted box with a freely selectable 55x55mm frame, Protection class IP 20, Colour Black screen border and white case, made of Glass and PVC
Suitable for: All units with control configuration KaControl MC1 and MC2
Suitable for: All units with control configuration KaControl MC1 and MC2
Article no.:
196003311101
Modbus TCP licence ex-works
Licence for activation of the Modbus TCP interface ex-works, Hardware for use of the interface is installed and activated
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Article no.:
196003361103
Modbus RTU licence ex-works
Licence for activation of the Modbus RTU interface ex-works, Hardware for use of the interface is installed and activated
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Article no.:
196003361102
BACnet/IP licence ex-works
Licence for activation of the BACnet/IP interface ex-works, Hardware for use of the interface is installed and activated
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Article no.:
196003361104
KNX licence ex-works
Licence for activation of the KNX interface ex-works, Hardware for use of the interface is installed and activated
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Article no.:
196003361101
Modbus TCP licence after delivery
Licence for activation of the Modbus TCP interface after delivery, Hardware with all units with KaControl MC is always installed and can be activated
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Article no.:
196003361203
Modbus RTU licence after delivery
Licence for activation of the Modbus RTU interface after delivery, Hardware with all units with KaControl MC is always installed and can be activated
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Article no.:
196003361202
BACnet/IP licence after delivery
Licence for activation of the BACnet/IP interface after delivery, Hardware with all units with KaControl MC is always installed and can be activated
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Article no.:
196003361204
KNX licence after delivery
Licence for activation of the KNX interface after delivery, Hardware with all units with KaControl MC is always installed and can be activated
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Article no.:
196003361201
Surface-mounted housing
Complete with cover frame, Surface-mounted, Colour RAL 9010 gloss pure white, made of Thermoplastic, Type 3304111
Suitable for: Touch Panel TP 2
Suitable for: Touch Panel TP 2
Article no.:
196003304111
Surface-mounted housing
Complete with cover frame, Surface-mounted, Colour RAL 9005 matt satin deep black, made of Thermoplastic, Type 3304112
Suitable for: Touch Panel TP 2
Suitable for: Touch Panel TP 2
Article no.:
196003304112
room temperature sensor
to detect the room temperature., Surface-mounted, Protection class IP 20, Colour RAL 9010 pure white, made of Polycarbonat, Type 3321111
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Article no.:
196003321111
Valve kits
Valve kit
Includes 1x pre-settable valve, straight, 1x return shut-off valve, straight, Max. operating pressure 10 bar
Suitable for: Katherm QK Trench Technology, DN 15
Suitable for: Katherm QK Trench Technology, DN 15
Article no.:
194000142111
Valve actuators, supplied loose
Valve actuator kit
Drive T, 24 V AC/DC, 2-point, normally closed, 0.5m connecting line-MB2, PVC, VA10N, 1 W, Protection class III, Protection class IP 54, Cable length 0.12 m, supplied separately, made of Polyamide
Suitable for: All units with electro-mechanical control configuration KaControl MC1, KaControl C1 in conjunction with 2-way valve or differential pressure-independent valve
Suitable for: All units with electro-mechanical control configuration KaControl MC1, KaControl C1 in conjunction with 2-way valve or differential pressure-independent valve
Article no.:
1960TS0P24050010B
Valves and return shut-off valves
Pre-adjustable valve kit
straight, pre-settable, Connection 1/2'', kvs value 1 m³/h, Max. operating pressure 10 bar
Suitable for: Katherm NK 182 (trench heights 150 mm and 200 mm), Katherm NK 232/300/380 (all trench heights), Katherm QK, DN 15
Suitable for: Katherm NK 182 (trench heights 150 mm and 200 mm), Katherm NK 232/300/380 (all trench heights), Katherm QK, DN 15
Article no.:
194000346909
Pre-setting key
Once per project necessary.
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Article no.:
194000346915
Return shut-off valve
Straight, Connection 1/2''
Suitable for: Katherm NK, Katherm QK or Katherm HK
Suitable for: Katherm NK, Katherm QK or Katherm HK
Article no.:
194000145952
Differential pressure-independent valve kit
Connection 1/2'', Max. operating pressure 10 bar, supplied separately
Suitable for: DN 15
Suitable for: DN 15
Article no.:
194000347913
Mitred corners
Mitred corner
Aluminium, natural anodised, 90 degrees, Bar depth 5 mm, Bar height 18 mm, Bar spacing 12 mm, Free area, approx. 70 %
Suitable for: Katherm QK
Suitable for: Katherm QK
Article no.:
194000142519
Mitred corner
Aluminium, natural anodised, other angles, Bar depth 5 mm, Bar height 18 mm, Bar spacing 12 mm, Free area, approx. 70 %
Suitable for: Katherm QK
Suitable for: Katherm QK
Article no.:
194000142619
Mitred corner
Aluminium, natural anodised, 90 degrees, Bar depth 5 mm, Bar height 18 mm, Bar spacing 12 mm, Free area, approx. 70 %
Suitable for: Katherm QK
Suitable for: Katherm QK
Article no.:
194000142719
Mitred corner
Aluminium, natural anodised, other angles, Bar depth 5 mm, Bar height 18 mm, Bar spacing 12 mm, Free area, approx. 70 %
Suitable for: Katherm QK
Suitable for: Katherm QK
Article no.:
194000142819
Installation covers
Installation cover
to protect trench during installation, factory-fitted, grilles are packed separately
price per m
Suitable for: Katherm QK
price per m
Suitable for: Katherm QK
Article no.:
194000100919
Downloads
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(194 kB)
Certificate ISO 9001:2008
PDF
(118 kB)
Digital EPD database Katherm QK
EPD for Katherm QK
PDF
(2.7 MB)
UKCA Declaration Katherm HK, QK, QK nano
PDF
(468 kB)
Cross-product information
Products
PDF
(10.7 MB)
Information sheet trench heating BS EN 16430 UK version
PDF
(215 kB)
Technical catalogues
KaControl MC - Multi Connect
PDF
(2.2 MB)
Katherm QK, QK nano trench heating
PDF
(12.7 MB)
Manuals
KaControl MC - Multi Connect
PDF
(1.3 MB)
Katherm QK, brief instructions
PDF
(4 MB)
Katherm QK trench heating
PDF
(5.1 MB)
Katherm QK - Wiring diagrams, control KaControl
PDF
(1.8 MB)
Katherm QK - Wiring Diagrams, electromechanical control
PDF
(1.2 MB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
CAD-Drawings
Katherm QK 190, PDF top view
PDF
(1.1 MB)
Katherm QK 190, PDF cross-sections
PDF
(88 kB)
Katherm QK 190, PDF front views
PDF
(131 kB)
Katherm QK 190, DWG top view
DWG
(3.8 MB)
Katherm QK 190, DWG cross-sections
DWG
(392 kB)
Katherm QK 190, DWG front views
DWG
(361 kB)
Installation plans
Katherm QK, KaControl MC version
PDF
(1.1 MB)