Fan Coils
KaCool W
Article no.:
32400122200000
Overview
- Simple removal is possible
- The ISO Coarse air filter can be regenerated by simply vacuuming it
An extremely energy-efficient EC motor is fitted in the KaCool W, the continuously variable operation of which guarantees precise adaptation to the output requirement. It also stands out with its low noise emissions.
- High-output copper-aluminium heat exchanger
- With high heat and cooling outputs
- Optimised in terms of air flow
- Louvre fins, manually adjustable, motorised adjustment with infra-red remote control version
- For adjustable air distribution and fewer draughts in any space
Different valve kits are available: 2-way, 3-way and differential pressure-independent valves combined with matching pipe connections and actuators
Optionally available for reliable condensate drainage
Calculate performance data
Sound power octave spectrum
The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
Oktave Spektrum
Accessories
Control accessories electromechanical 230 V
Room thermostat
Heating/Cooling, 2- and 4-pipe, 3-stage. Only in conjunction with valves/valve kits with actuator, with OFF/Manual/Automatic fan switchover, 230 V AC, Open/Closed, Surface-mounted, Protection class II, Protection class IP 30, Temperature setting range 5 - 30 °C, Colour similar to RAL 9010 pure white, Type 30155
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units electromechanical, 5 Katherm HK Trench Technology, 5 TOP, Ultra or Ultra Allround Unit Heaters, 5 Venkon or PowerKon LT Fan Coils, 5 KaCool D AF, KaCool W or KaDeck Fan Coils
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units electromechanical, 5 Katherm HK Trench Technology, 5 TOP, Ultra or Ultra Allround Unit Heaters, 5 Venkon or PowerKon LT Fan Coils, 5 KaCool D AF, KaCool W or KaDeck Fan Coils
Article no.:
196000030155
Clock thermostat
Heating/Cooling, 2- and 4-pipe, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, 1 W, flush-mounted, Protection class II, Protection class IP 30, Colour similar to RAL 9010 pure white, Type 30256
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units electromechanical, 5 TOP, Ultra or Ultra Allround Unit Heaters, 5 Venkon Fan Coils, 5 KaCool D AF, KaCool W or KaDeck Fan Coils
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units electromechanical, 5 TOP, Ultra or Ultra Allround Unit Heaters, 5 Venkon Fan Coils, 5 KaCool D AF, KaCool W or KaDeck Fan Coils
Article no.:
196000030256
Climate Controller
Heating/Cooling, 2- and 4-pipe, without Modbus, only with valves/valve kits Open/Closed, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9010 pure white, Type 148941
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.:
196000148941
Climate Controller
Heating/Cooling, 2- and 4-pipe, without Modbus, only with valves/valve kits Open/Closed, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9004 signal black, Type 148942
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.:
196000148942
Climate Controller
Heating/Cooling, 2- and 4-pipe, with Modbus, only with valves/valve kits Open/Closed, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9010 pure white, Type 148943
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.:
196000148943
Climate Controller
Heating/Cooling, 2- and 4-pipe, with Modbus, only with valves/valve kits Open/Closed, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9004 signal black, Type 148944
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.:
196000148944
Valve kits
Differential pressure-independent valve kit
2-pipe, 230 V 2-point actuator 230 V Open/Close, 50 Hz, Connection 1/2'' Max. operating pressure 16 bar, supplied separately
Valve kit for Kampmann KaCool W wall units for on-site assembly.
Suitable for: Model size 1 - 4, Min. Flow volume 65 l/h, max. Flow volume 650 l/h, DN 15
Valve kit for Kampmann KaCool W wall units for on-site assembly.
Suitable for: Model size 1 - 4, Min. Flow volume 65 l/h, max. Flow volume 650 l/h, DN 15
Article no.:
324002012130
2-way valve kit
2-pipe, 1 St. 230 V 2-point actuator 230 V Open/Close, 50 Hz, Connection 1/2'' kvs value 1.7 m³/h, Max. operating pressure 16 bar, supplied separately
Valve kit for Kampmann KaCool W wall units for on-site assembly.
Suitable for: Model size 1 - 4, DN 15
Valve kit for Kampmann KaCool W wall units for on-site assembly.
Suitable for: Model size 1 - 4, DN 15
Article no.:
324002012110
3-way valve kit
2-pipe, 1 St. 230 V 2-point actuator 230 V Open/Close, 50 Hz, Connection 1/2'' kvs value 1.7 m³/h, Max. operating pressure 16 bar, supplied separately
Valve kit for Kampmann KaCool W wall units for on-site assembly.
Suitable for: Model size 1 - 4, DN 15
Valve kit for Kampmann KaCool W wall units for on-site assembly.
Suitable for: Model size 1 - 4, DN 15
Article no.:
324002012120
Condensate tray/pump
Condensate drain
alternative to a free drain, 230 V 50 Hz, 19 W, supplied separately
Suitable for: KaCool W AC Fan Coils
Suitable for: KaCool W AC Fan Coils
Article no.:
324002000410
Additional colours
surcharge for RAL colour of your choice
Price per unit.
Suitable for: Model size 1 - 2, KaCool W Fan Coils
Suitable for: Model size 1 - 2, KaCool W Fan Coils
Article no.:
324002000101
Downloads
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(194 kB)
Certificate ISO 9001:2008
PDF
(118 kB)
Cross-product information
Products
PDF
(10.7 MB)
Manuals
KaControl for Airblock KG
PDF
(34.1 MB)
KaCool W Fan Coils (FCU)
PDF
(4.2 MB)
KaCool W, brief guide
PDF
(1.1 MB)
CAD-Drawings
Fan Coil KaCool W, Baugroesse 1 - 4, PDF
PDF
(382 kB)
Fan Coil KaCool W, Bohrschablone BG 1 - 2, PDF
PDF
(217 kB)
Fan Coil KaCool W, Bohrschablone BG 3 - 4, PDF
PDF
(221 kB)
Fan Coil KaCool W, Baugroesse 1 - 4, DWG
DWG
(551 kB)
Fan Coil KaCool W, Bohrschablone BG 1 - 2, DWG
DWG
(348 kB)
Fan Coil KaCool W, Bohrschablone BG 3 - 4, DWG
DWG
(350 kB)
Technical catalogues
KaCool W
PDF
(5 MB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
Installation plans
Verlegepläne KaCool W elektromechanisch
PDF
(710 kB)