Fan Coils
LOGO_KAMPMANN_BLAU

KaDeck

Article no.: 32612646211100
Use the dropdown menus to quickly and simply adapt the figures to your requirements.
32612646211100

Overview

Calculate performance data

Sound power octave spectrum

The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
Oktave Spektrum
EPD data

Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary

A B C D
GWP - Total kg CO2 eq 1.70E+02 1.87E+01 4.02E+00 -4.80E+01
GWP - fossil kg CO2 eq 1.66E+02 1.72E+01 3.96E+00 -4.74E+01
GWP - Biogenic kg CO2 eq 2.94E+00 1.40E+00 5.64E-02 -5.14E-01
GWP - Luluc kg CO2 eq 1.04E+00 8.00E-02 9.62E-05 -6.11E-02
ODP kg CFC-11 eq 3.43E-06 2.36E-07 6.11E-09 -9.45E-07
AP mol H+ eq 1.77E+00 9.78E-02 1.12E-03 -8.74E-01
EP - fresh water kg P eq 1.47E-01 2.50E-02 2.11E-05 -7.75E-02
EP - marine kg P eq 1.99E-01 1.52E-02 4.51E-04 -7.01E-02
EP - country mol N eq 2.13E+00 1.33E-01 4.75E-03 -8.42E-01
POCP kg NMVOC 7.70E-01 4.07E-02 1.68E-03 -2.94E-01
ADPE kg Sb eq 1.39E-02 7.42E-04 5.52E-07 -9.15E-03
ADPF MJ 2.29E+03 2.56E+02 3.28E+00 -7.03E+02
WDP m³ depriv. 3.42E+01 1.84E+00 5.13E-02 -1.54E+01
GWP-GHG kg CO2 eq 1.69E+02 1.75E+01 3.96E+00 -4.77E+01
PM disease inc. 1.25E-05 4.84E-07 2.39E-08 -3.37E-06
IR kBq U-235 eq 1.94E+01 3.86E+00 7.03E-03 -1.13E+01
HTP - C CTUh 5.96E-07 2.25E-08 1.04E-08 -2.17E-07
HTP - NC CTUh 1.61E-05 8.59E-07 6.78E-07 -9.57E-06
SQP - 9.42E+02 7.03E+01 4.40E+00 -3.19E+02
PERE MJ 4.17E+02 7.42E+01 1.17E-01 -1.02E+02
PERM MJ 0.00E+00 0.00E+00 0.00E+00 0.00E+00
PERT MJ 4.17E+02 7.42E+01 1.17E-01 -1.02E+02
PENRE MJ 2.29E+03 2.56E+02 2.34E+00 -7.03E+02
PENRM MJ 0.00E+00 0.00E+00 0.00E+00 0.00E+00
PENRT MJ 2.29E+03 2.56E+02 2.34E+00 -7.03E+02
SM kg 4.36E-01 0.00E+00 0.00E+00 0.00E+00
RSF MJ 0.00E+00 0.00E+00 0.00E+00 0.00E+00
NRSF MJ 0.00E+00 0.00E+00 0.00E+00 0.00E+00
FW m³ 1.89E+00 1.36E-01 1.87E-02 -4.03E-01
HWD kg 0.00E+00 0.00E+00 0.00E+00 0.00E+00
NHWD kg 6.04E+00 0.00E+00 0.00E+00 0.00E+00
RWD kg 0.00E+00 0.00E+00 0.00E+00 0.00E+00
CRU kg 0.00E+00 0.00E+00 0.00E+00 0.00E+00
MFR kg 0.00E+00 0.00E+00 1.68E+01 0.00E+00
MER kg 0.00E+00 0.00E+00 1.04E+00 0.00E+00
EE (Electrical) MJ 0.00E+00 0.00E+00 0.00E+00 0.00E+00
EE (Thermal) MJ 0.00E+00 0.00E+00 0.00E+00 0.00E+00

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist

Accessories

Control accessories electromechanical 230 V
Room thermostat

Room thermostat

Heating/Cooling, 2- and 4-pipe, 3-stage. Only in conjunction with valves/valve kits with actuator, with OFF/Manual/Automatic fan switchover, 230 V AC, Open/Closed, Surface-mounted, Protection class II, Protection class IP 30, Temperature setting range 5 - 30 °C, Colour similar to RAL 9010 pure white, Type 30155
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922

Suitable for: EC units electromechanical, 5 Katherm HK Trench Technology, 5 TOP, Ultra or Ultra Allround Unit Heaters, 5 Venkon or PowerKon LT Fan Coils, 5 KaCool D AF, KaCool W or KaDeck Fan Coils
Article no.: 196000030155

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Clock thermostat

Clock thermostat

Heating/Cooling, 2- and 4-pipe, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, 1 W, flush-mounted, Protection class II, Protection class IP 30, Colour similar to RAL 9010 pure white, Type 30256
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922

Suitable for: EC units electromechanical, 5 TOP, Ultra or Ultra Allround Unit Heaters, 5 Venkon Fan Coils, 5 KaCool D AF, KaCool W or KaDeck Fan Coils
Article no.: 196000030256

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Climate Controller

Climate Controller

Heating/Cooling, 2- and 4-pipe, without Modbus, only with valves/valve kits Open/Closed, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9010 pure white, Type 148941

Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.: 196000148941

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Climate Controller

Climate Controller

Heating/Cooling, 2- and 4-pipe, without Modbus, only with valves/valve kits Open/Closed, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9004 signal black, Type 148942

Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.: 196000148942

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Climate Controller

Climate Controller

Heating/Cooling, 2- and 4-pipe, with Modbus, only with valves/valve kits Open/Closed, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9010 pure white, Type 148943

Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.: 196000148943

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Climate Controller

Climate Controller

Heating/Cooling, 2- and 4-pipe, with Modbus, only with valves/valve kits Open/Closed, continuous fan control, with LCD operating menu and integrated timer program, 230 V AC, Open/Closed, Surface-mounted, Protection class IP 30, Temperature setting range 0 - 50 °C, Colour similar to RAL 9004 signal black, Type 148944

Suitable for: EC units electromechanical, 4 Katherm HK Trench Technology, 4 KaCool D AF, KaCool W, Venkon or KaDeck Fan Coils, 4 Ultra Allround Unit Heaters
Article no.: 196000148944

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Valve kits
Differential pressure-independent valve kit

Differential pressure-independent valve kit

Connection R1/2” male thread Cu-DN12, 4-pipe, Actuator, return shut-off valve and flexible connection, corrugated stainless steel pipe flow and return, Protection class IP 54, water with glycol <50%, supplied separately

Suitable for: KaDeck Fan Coils, DN 15
Article no.: 326007114020

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Differential pressure-independent valve kit

Differential pressure-independent valve kit

Connection R1/2” male thread Cu-DN12, 4-pipe, Actuator, return shut-off valve and flexible connection, corrugated stainless steel pipe flow and return, Protection class IP 54, water with glycol <50%, supplied separately

Suitable for: KaDeck Fan Coils, DN 15
Article no.: 326007114030

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Pre-adjustable valve kit

Pre-adjustable valve kit

Connection R1/2” male thread Cu-DN12, 4-pipe, Actuator, return shut-off valve and flexible connection, corrugated stainless steel pipe flow and return, 2-way valve, pre-settable, Protection class IP 54, water with glycol <50%, supplied separately

Suitable for: KaDeck Fan Coils, DN 15
Article no.: 326007114040

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Valve actuator kits

Valve actuator kit

Drive T, 24 V AC/DC, 0 - 10 V, normally closed, 1.2 W, Protection class III, Protection class IP 54, supplied separately, made of Polyamide

Article no.: 1960TV8H04462210B

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details

Valve actuator kit

Drive T, 24 V AC/DC, 2-point, normally closed, 1 W, Protection class III, Protection class IP 54, Cable length 0.12 m, supplied separately, made of Polyamide

Article no.: 1960TS8P04050010B

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Attachments
Primary air connection spigot

Primary air connection spigot

Connection DN 80, for the connection of external primary air

Suitable for: KaDeck Fan Coils
Article no.: 326007010104

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Primary air connection spigot

Primary air connection spigot

Connection DN 80, for the connection of external primary air

Suitable for: KaDeck fan coils with under-ceiling frame without recesses, KaDeck Fan Coils
Article no.: 326007200001

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Under-ceiling frame

Under-ceiling frame

Connection Top, without recesses

Suitable for: KaDeck Fan Coils
Article no.: 326007200000

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Under-ceiling frame

Under-ceiling frame

Connection Side, 4-pipe, without supply air spigots, 2-way valve, pre-settable

Suitable for: KaDeck Fan Coils
Article no.: 326007241100

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Under-ceiling frame

Under-ceiling frame

Connection Side, 4-pipe, supply air spigot on both sides, 2-way valve, pre-settable

Suitable for: KaDeck Fan Coils
Article no.: 326007241130

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Under-ceiling frame

Under-ceiling frame

Connection Side, 4-pipe, electrical-side supply air spigot, 2-way valve, pre-settable

Suitable for: KaDeck Fan Coils
Article no.: 326007241120

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Under-ceiling frame

Under-ceiling frame

Connection Side, 4-pipe, water-side supply air spigot, 2-way valve, pre-settable

Suitable for: KaDeck Fan Coils
Article no.: 326007241110

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Under-ceiling frame

Under-ceiling frame

Connection Side, 4-pipe, without supply air spigots, Differential pressure-independent valve kit

Suitable for: KaDeck Fan Coils
Article no.: 326007241200

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Under-ceiling frame

Under-ceiling frame

Connection Side, 4-pipe, supply air spigot on both sides, Differential pressure-independent valve kit

Suitable for: KaDeck Fan Coils
Article no.: 326007241230

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Under-ceiling frame

Under-ceiling frame

Connection Side, 4-pipe, electrical-side supply air spigot, Differential pressure-independent valve kit

Suitable for: KaDeck Fan Coils
Article no.: 326007241220

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Under-ceiling frame

Under-ceiling frame

Connection Side, 4-pipe, water-side supply air spigot, Differential pressure-independent valve kit

Suitable for: KaDeck Fan Coils
Article no.: 326007241210

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Additional colours
Surcharge for RAL standard colour

surcharge for RAL standard colour

Price per unit.

Suitable for: KaDeck Fan Coils
Article no.: 326007010011

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Surcharge for RAL colour of your choice

surcharge for RAL colour of your choice

Minimum quantity = 7 units per order and colour, The number of units below the minimum quantity must be requested and calculated separately.
Price per unit.

Suitable for: KaDeck Fan Coils
Article no.: 326007010021

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details
Surcharge for change of colour

surcharge for change of colour

of the powder-coating to the colour version quoted., The surcharge includes the conversion and cleaning of the powder-coating to the requested colour and will be charged once per project and call-off order.

Suitable for: KaDeck or KaDeck UC Fan Coils
Article no.: 326007010010

Product has been added

view wish list
To create wish lists, you have to log in or re-register .
Add to my wishlist
Details

Downloads

Declarations/Certificates
Certificate ISO 50001:2018
PDF (194 kB)
Certificate ISO 9001:2008
PDF (118 kB)
EU Declaration of Conformity KaDeck fan coils (FCU)
PDF (456 kB)
UKCA Declaration KaDeck
PDF (462 kB)
digital EPD database for the KaDeck, two-sided discharge, wet cooling
EPD KaDeck two-sided air outlet, wet cooling
PDF (9.2 MB)
Cross-product information
Products
PDF (10.7 MB)
Technical catalogues
KaDeck fan coils (FCU)
PDF (9.9 MB)
Manuals
KaDeck fan coils (FCU)
PDF (7.7 MB)
KaDeck, brief instructions
PDF (4.4 MB)
KaDeck maintenance video
KaDeck assembly video
CAD-Drawings
Fan Coil KaDeck Zwischendecke, Luftauslass einseitig und zweiseitig, Ansicht Wurfweitenvergleich
PDF (421 kB)
Fan Coil KaDeck Zwischendecke, Luftauslass einseitig und zweiseitig, Abmessungen
PDF (606 kB)
Fan Coil KaDeck Zwischendecke, Luftauslass einseitig und zweiseitig, Abmessungen
DWG (1.8 MB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
Installation plans
Verlegepläne KaDeck elektromechanisch
PDF (695 kB)