Unit Heaters
TOP C
Article no.:
153002474056C1
Overview
- Self-priming, fixed to the hose connector for the on-site condensate pressurised line
- Electromagnetically working pump, energy-saving and quiet with a delivery height of up to 8 m
- Fully connected, easily accessible float switch below the condensate tray
- With alarm contact for on-site evaluation
- Copper/aluminium heat exchanger, especially lightweight, with high heat outputs from minimal dimensions
- Suitable for low temperature heating systems and LPHW heating systems
- Steel distributor and collector
- Not suitable for steam and thermal oil
- Hollow copper tubes with aluminium fins, connected by expanded pipes, perfect for lasting heat transfer
- Cannot be used in areas with high levels of dust or oil in which extensive cleaning is needed
- Continuously variable EC single-phase whisper-quiet sickle-blade fan (see Fig.)
- Highly efficient due to the aerodynamic design of the rotor housing
- Motor protection class IP 54
- Balanced according to DIN ISO 21940-11 and according to ISO 14694 for the corresponding fan category, external rotor motor integrated in the fan impeller
- External rotor motor integrated in the fan impeller
- Complies with Directive (EU) 327/2011 (“LOT 11”)
Accessories
Control accessories KaControl
KaController
with one-button operation, 24 V, wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9010 pure white, made of resistant PVC, Type 3210001
Suitable for: All units with control configuration KaControl C1
Suitable for: All units with control configuration KaControl C1
Article no.:
196003210001
KaController
with one-button operation, 24 V, wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9017 traffic black, made of resistant PVC, Type 3210006
Suitable for: All units with control configuration KaControl C1
Suitable for: All units with control configuration KaControl C1
Article no.:
196003210006
KaController
with side operating keys, 24 V, wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9010 pure white, made of resistant PVC, Type 3210002
Suitable for: All units with control configuration KaControl C1
Suitable for: All units with control configuration KaControl C1
Article no.:
196003210002
Industry KaController
industrial housing with hinged transparent cover, lockable, with side operating keys, Surface-mounted, Protection class IP 65, Colour grey, made of plastic, Type 3214002
Suitable for: All units with control configuration KaControl C1, ProtecTor Door Air Curtains
Suitable for: All units with control configuration KaControl C1, ProtecTor Door Air Curtains
Article no.:
196003214002
room temperature sensor
Wall-mounted, Surface-mounted, Protection class IP 30, Colour similar to RAL 9010 pure white, made of plastic, Type 3250110
Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Article no.:
196003250110
Outside temperature sensor/industrial temperature sensor
Surface-mounted, Protection class IP 65, Colour similar to RAL 9010 pure white, Type 3250112
Suitable for: All units with control configuration KaControl C1, ProtecTor Door Air Curtains
Suitable for: All units with control configuration KaControl C1, ProtecTor Door Air Curtains
Article no.:
196003250112
Clip-on pipe sensor
to detect the medium temperature, Protection class IP 67, Temperature setting range -20 - 70 °C, Colour black, Type 3250115
Is there a risk of frost, e.g. due to the ingress of cold air – if so, then a KaControl clip-on pipe sensor should be chosen for each unit!
heating/cooling changeover function only in conjunction with 3-way valve!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Is there a risk of frost, e.g. due to the ingress of cold air – if so, then a KaControl clip-on pipe sensor should be chosen for each unit!
heating/cooling changeover function only in conjunction with 3-way valve!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Article no.:
196003250115
KaControl Tableau SEL4.0
with touch terminal, to monitor and control up to 60 Kampmann secondary air units (maximum 25 groups, maximum 6 units per group), 230 V AC, 30 W, Wall-mounted, Protection class IP 54, Colour RAL 7035 grey, Type 3232223
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101
Article no.:
196003232223
Serial KNX card
for integration into a KNX/EIB network, interface PCOS00KXN0, Type 3260702
The communication card slots into the free interface on the PCB.
Suitable for: All units with control configuration KaControl C1
The communication card slots into the free interface on the PCB.
Suitable for: All units with control configuration KaControl C1
Article no.:
196003260702
Serial CANbus card
to increase the number of units in a single-circuit system from 7 to a maximum of 30 units, one required per unit, Extension of the cable length from the first to the last unit from 30 m to 500 m, Can only be used with the KaControl -C1 control version!The room temperature cannot be recorded by a room sensor when using CanBus cards., Type 3260301
Suitable for: All units with control configuration KaControl C1
Suitable for: All units with control configuration KaControl C1
Article no.:
196003260301
Serial Modbus card
Type 3260101
Required for each device for connection to KaControl panels or on-site Modbus networks.
The communication card slots into the free interface on the PCB.
Suitable for: All units with control configuration KaControl C1
Required for each device for connection to KaControl panels or on-site Modbus networks.
The communication card slots into the free interface on the PCB.
Suitable for: All units with control configuration KaControl C1
Article no.:
196003260101
KaControl visualisation
for the central monitoring and control of air handling units, Type 3210701
The KaControl visualisation unit is used to monitor and control individual control zones and secondary air units for 4-pipe heating/cooling, 2-pipe heating or 2-pipe cooling.
The central interface for monitoring Kampmann products provides optimum assistance with technical monitoring.
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101, 100 Units
The KaControl visualisation unit is used to monitor and control individual control zones and secondary air units for 4-pipe heating/cooling, 2-pipe heating or 2-pipe cooling.
The central interface for monitoring Kampmann products provides optimum assistance with technical monitoring.
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101, 100 Units
Article no.:
196003210701
KaControl visualisation
for the central monitoring and control of air handling units, Type 3210702
The KaControl visualisation unit is used to monitor and control individual control zones and secondary air units for 4-pipe heating/cooling, 2-pipe heating or 2-pipe cooling.
The central interface for monitoring Kampmann products provides optimum assistance with technical monitoring.
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101, 300 Units
The KaControl visualisation unit is used to monitor and control individual control zones and secondary air units for 4-pipe heating/cooling, 2-pipe heating or 2-pipe cooling.
The central interface for monitoring Kampmann products provides optimum assistance with technical monitoring.
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101, 300 Units
Article no.:
196003210702
Valve kits
2-way valve kit
as a straight valve body, Connection 1 1/2'', kvs value 10 m³/h, Type 31913
Not in conjunction with 2-stage three-phase switch art. no. 196000030049!
Suitable for: all unit heaters
Not in conjunction with 2-stage three-phase switch art. no. 196000030049!
Suitable for: all unit heaters
Article no.:
153000031913
Control shut-off valve
with reducer 1 1/4 inch x 1 1/2 inch m/f, for automatic flow and temperature control, kvs value 8.4 m³/h, Type 31952
Suitable for: Model size 6 - 8, TOP Unit Heaters, Min. Flow volume 600 l/h, max. Flow volume 4800 l/h, DN 32
Suitable for: Model size 6 - 8, TOP Unit Heaters, Min. Flow volume 600 l/h, max. Flow volume 4800 l/h, DN 32
Article no.:
153000031952
Valve actuators, supplied loose
Valve actuator kit
Drive T, 24 V AC/DC, 2-point, normally closed, 3m connecting line-AEH, PVC, VA10N, 1 W, Protection class III, Protection class IP 54, Cable length 0.12 m, supplied separately, made of Polyamide
Suitable for: All units with electro-mechanical control configuration KaControl C1 in conjunction with 2-way valve or differential pressure-independent valve
Suitable for: All units with electro-mechanical control configuration KaControl C1 in conjunction with 2-way valve or differential pressure-independent valve
Article no.:
1960TS3P04050010B
Valves
Unit heater shut-off set, angled version
Connection 1 1/2'', Max. operating pressure 10 bar, Type 37976
Suitable for: Model size 7
Suitable for: Model size 7
Article no.:
198000037976
Unit heater shut-off set, straight version
Connection 1 1/2'', Max. operating pressure 10 bar, Type 37977
Suitable for: Model size 7
Suitable for: Model size 7
Article no.:
198000037977
Air outlets
calculation-relevant accessory
Louvre
two-row for wall- and ceiling-mounted units
Suitable for: Model size 7
Suitable for: Model size 7
Article no.:
198000037002
Induction air outlet louvre
calculation-relevant accessory
mainly used for wall-mounted units, for ceiling-mounted units with ceiling heights of more than 4.0 m
Suitable for: Model size 7
Suitable for: Model size 7
Article no.:
198000037101
Brackets
Wall brackets
recirculating air only, made of sendzimir galvanised sheet steel for wall mounting, a complete set
TIP and TOP unit heaters can be installed standing and also suspended.
price for 1 complete set
Suitable for: Model size 7
TIP and TOP unit heaters can be installed standing and also suspended.
price for 1 complete set
Suitable for: Model size 7
Article no.:
198000037044
Ceiling-wall brackets
for ceiling or wall mounting, consisting of 2 multi-edged brackets with slotted holes and screws
price for 1 complete set
Suitable for: Model size 7
price for 1 complete set
Suitable for: Model size 7
Article no.:
198000037049
Downloads
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(194 kB)
Certificate ISO 9001:2008
PDF
(118 kB)
UKCA Declaration Unit Heater
PDF
(450 kB)
ErP Data Sheet for TOP unit heaters
PDF
(234 kB)
Cross-product information
Products
PDF
(10.7 MB)
Technical catalogues
KaControl MC - Multi Connect
PDF
(2.2 MB)
Manuals
KaControl MC - Multi Connect
PDF
(1.3 MB)
TOP unit heaters
PDF
(7.7 MB)
CAD-Drawings
TOP C unit heater, size 4 - 7, copper/aluminium heat exchanger [inch]
PDF
(219 kB)
TOP C unit heater, size 4 - 7, copper/aluminium heat exchanger [mm]
PDF
(223 kB)
TOP C Lufterhitzer, Baugröße 44 - 47, Wärmetauscher Kupfer/Aluminium [Inch]
DWG
(507 kB)
TOP C Lufterhitzer, Baugröße 44 - 47, Wärmetauscher Kupfer/Aluminium [mm]
DWG
(507 kB)