Unit Heaters
TOP
Article no.:
153000453158FR
Overview
Its robust and durable steel construction enables dirty heating elements to be cleaned using high-pressure cleaners or compressed air without the risk of damaging the heat exchanger.
- Suitable for LPHW and thermal oil.
- Galvanised elliptical core pipe.
- Galvanised steel slats.
- Permanent corrosion protection through galvanising.
- Suitable for continuous operating pressures up to 16 bar, 120 °C.
High-pressure versions and versions for temperatures above 120 °C are available on request.
- Stepless EC AC fan (see figure)
- Highly efficient due to the aerodynamic design of the rotor housing
- Motor protection class IP 54
- Optional 2-stage wide-blade fan with explosion-proof AC external rotor motor (IP 44)
- Copper-aluminium heat exchanger (see Fig.), extremely lightweight, with high heat outputs and low dimensions, suitable for low temperature heating systems and LPHW heating systems, steel header and manifold
- Steel heat exchanger, galvanised, robust and durable
- Steel heat exchanger, galvanised steel, cross-counterflow, particularly suitable for high water temperature spreads
- Steel heat exchanger, galvanised, for steam
Ultra-efficient as a component in a hybrid system: while the TOP has decentralised temperature control, an air handling unit with small dimensions deals with ventilation and heat recovery. This saves operating costs as all components only work when demand is detected. And you benefit from the reduced size of the air handling unit in terms of investment and installation.
It is operated for example using a thermostat, KaControl Touch Panel or by linking it into the building automation via Modbus, KNX, or BACnet.
However you plan to heat, TOP unit heaters do the job with the suitable heat exchanger. Copper/aluminium or galvanised steel for PWW/PHW (for low temperature operation as well), cross-counterflow heat exchanger with large temperature spreads, and on request, with a special version for steam.
Accessories
Switching and control units – Mixed air / fresh air, electro-mechanical
Servomotor
can be reversed, 230 V Open/Closed, Protection class IP 54, Type 30262
Suitable for: KaMAX
Suitable for: KaMAX
Article no.:
196000030262
Valve kits
Unit heater shut-off set, angled version
Connection 1'', Type 35976
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000035976
Unit heater shut-off set, straight version
Connection 1'', Type 35977
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000035977
Valve actuators, supplied loose
valve actuator
Drive T, 230 V AC, 2-point, normally closed, 3m connecting line-AEH, PVC, VA10N, 1 W, Protection class II, Protection class IP 54 Cable length 0.12 m, supplied separately, made of Polyamide
Suitable for: All units with electro-mechanical control configuration in conjunction with 2-way valve or differential pressure-independent valve
Suitable for: All units with electro-mechanical control configuration in conjunction with 2-way valve or differential pressure-independent valve
Article no.:
196TS3P020500AB
Valves
2-way valve kit
as a straight valve body, Connection 1'', kvs value 3.3 m³/h, Type 31911
Suitable for: all unit heaters
Suitable for: all unit heaters
Article no.:
153000031911
Control shut-off valve
for automatic flow and temperature control, Connection 1'', kvs value 3.1 m³/h, Type 31950
Suitable for: Model size 4 - 5, TOP or Ultra Unit Heaters, Min. Flow volume 250 l/h, max. Flow volume 1800 l/h, DN 20
Suitable for: Model size 4 - 5, TOP or Ultra Unit Heaters, Min. Flow volume 250 l/h, max. Flow volume 1800 l/h, DN 20
Article no.:
153000031950
Control shut-off valve
for automatic flow and temperature control, Connection 1'', kvs value 4.1 m³/h, Type 31951
Suitable for: Model size 4 - 6, TOP or Ultra Unit Heaters, Min. Flow volume 400 l/h, max. Flow volume 2500 l/h, DN 25
Suitable for: Model size 4 - 6, TOP or Ultra Unit Heaters, Min. Flow volume 400 l/h, max. Flow volume 2500 l/h, DN 25
Article no.:
153000031951
Air outlets, supplied loose
calculation-relevant accessory
KaMAX
calculation-relevant accessory
Multi Air MiX for ceiling-mounted units, manual level adjustment, supplied separately
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000035111
KaMAX Open-Stop-Close switch
for electrically actuated continuously variable manual adjustment of the KaMAX louvre, supplied separately
Article no.:
196000030115
Louvre
two-row for wall- and ceiling-mounted units, supplied separately
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000035002
Induction air outlet louvre
calculation-relevant accessory
mainly used for wall-mounted units, for ceiling-mounted units with ceiling heights of more than 4.0 m, supplied separately
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000035101
Diffuser
calculation-relevant accessory
in four directions, for ceiling-mounted units, supplied separately
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000035004
Outlet nozzle
calculation-relevant accessory
for ceiling-mounted units, especially for high-ceilinged buildings, sendzimir galvanised, supplied separately
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000035006
Air outlets, fitted
calculation-relevant accessory
KaMAX
calculation-relevant accessory
Multi Air MiX for ceiling-mounted units, manual level adjustment, factory-fitted
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000135111
Louvre
two-row for wall- and ceiling-mounted units, factory-fitted
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000135002
Induction air outlet louvre
calculation-relevant accessory
mainly used for wall-mounted units, for ceiling-mounted units with ceiling heights of more than 4.0 m, factory-fitted
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000135101
Brackets
Universal 2-point brackets
recirculating air only, 1 complete set
Suitable for: Model size 4 - 8
Suitable for: Model size 4 - 8
Article no.:
198000030041
Universal 4-point brackets
recirculating air only, made of sendzimir galvanised sheet steel, as a 4-point fixing for ceiling installation, 1 complete set
Suitable for: Model size 4 - 8
Suitable for: Model size 4 - 8
Article no.:
198000030042
Universal 2-point T-support brackets
recirculating air only, Ceiling-mounted
Suitable for: Model size 4 - 8
Suitable for: Model size 4 - 8
Article no.:
198000030047
Wall brackets
recirculating air only, made of sendzimir galvanised sheet steel for wall mounting, a complete set
TIP and TOP unit heaters can be installed standing and also suspended.
price for 1 complete set
Suitable for: Model size 5
TIP and TOP unit heaters can be installed standing and also suspended.
price for 1 complete set
Suitable for: Model size 5
Article no.:
198000035044
Ceiling-wall brackets
for ceiling or wall mounting, consisting of 2 multi-edged brackets with slotted holes and screws
price for 1 complete set
Suitable for: Model size 5
price for 1 complete set
Suitable for: Model size 5
Article no.:
198000035049
Downloads
Declarations/Certificates
Certificate ISO 9001, 14001, 50001
PDF
(116 kB)
UKCA Declaration Unit Heater
PDF
(450 kB)
ErP Data Sheet for TOP unit heaters
PDF
(234 kB)
General product information
Products
PDF
(10.7 MB)
Technical catalogues
TOP unit heaters
PDF
(5.1 MB)
KaControl MC - Multi Connect
PDF
(2.2 MB)
TOP unit heaters
PDF
(18.7 MB)
Manuals
TOP unit heaters
PDF
(9.4 MB)
KaControl MC - Multi Connect Climate Control Quick Start Guide
PDF
(2.3 MB)
TOP unit heaters, brief instructions
PDF
(4.1 MB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
CAD-Drawings
TOP Lufterhitzer, Baugröße 44 - 47, Zubehör Luftlenkjalousie, 2-reihig
PDF
(727 kB)
TOP Lufterhitzer, Baugröße 44 - 48, Zubehör Luftlenkjalousie, 1-reihig
PDF
(241 kB)
TOP Lufterhitzer, Baugröße 44 - 48, Zubehör KaMax
PDF
(354 kB)
TOP Lufterhitzer, Baugröße 44 - 47, Zubehör Induktionsluftlenkjalousie
PDF
(703 kB)
TOP Lufterhitzer, Baugröße 44 - 48, Wärmetauscher Stahl verzinkt
PDF
(385 kB)
TOP Lufterhitzer, Baugröße 44 - 47, Zubehör Luftlenkjalousie, 2-reihig
DWG
(516 kB)
TOP Lufterhitzer, Baugröße 44 - 48, Zubehör Luftlenkjalousie, 1-reihig
DWG
(468 kB)
TOP Lufterhitzer, Baugröße 44 - 48, Zubehör KaMax
DWG
(1012 kB)
TOP Lufterhitzer, Baugröße 44 - 47, Zubehör Induktionsluftlenkjalousie
DWG
(516 kB)
TOP Lufterhitzer, Baugröße 44 - 48, Wärmetauscher Stahl verzinkt
DWG
(753 kB)
Installation plans
TOP, electromechanical control version
PDF
(1.1 MB)