Unit Heaters
TOP
Article no.:
153000454056C1
Overview
This type of heat exchanger is characterised by its low weight and high heat outputs.
- Suitable for LPHW 120 °C and 16 bar continuous operating pressure.
- Aluminium slats permanently connected by pipe expansion.
- Steel header and manifold.
Copper-aluminium heat exchangers are not suitable for use with steam and thermal oil systems.
Steel heat exchangers are recommended if throughout cleaning is required.
- Continuously variable EC single-phase whisper-quiet sickle-blade fan (see Fig.)
- Highly efficient due to the aerodynamic design of the rotor housing
- Motor protection class IP 54
- Optional 2-stage wide-blade fan with explosion-proof AC external rotor motor (IP 44)
- Copper-aluminium heat exchanger (see Fig.), extremely lightweight, with high heat outputs and low dimensions, suitable for low temperature heating systems and LPHW heating systems, steel header and manifold
- Steel heat exchanger, galvanised, robust and durable
- Steel heat exchanger, galvanised steel, cross-counterflow, particularly suitable for high water temperature spreads
- Steel heat exchanger, galvanised, for steam
Ultra-efficient as a component in a hybrid system: while the TOP has decentralised temperature control, an air handling unit with small dimensions deals with ventilation and heat recovery. This saves operating costs as all components only work when demand is detected. And you benefit from the reduced size of the air handling unit in terms of investment and installation.
It is operated for example using a thermostat, KaControl Touch Panel or by linking it into the building automation via Modbus, KNX, or BACnet.
However you plan to heat, TOP unit heaters do the job with the suitable heat exchanger. Copper/aluminium or galvanised steel for PWW/PHW (for low temperature operation as well), cross-counterflow heat exchanger with large temperature spreads, and on request, with a special version for steam.
Accessories
Control accessories KaControl
KaController
with one-button operation, 24 V, wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9010 pure white, made of resistant PVC, Type 3210001
Suitable for: All units with control configuration KaControl C1
Suitable for: All units with control configuration KaControl C1
Article no.:
196003210001
KaController
with one-button operation, 24 V, wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9017 traffic black, made of resistant PVC, Type 3210006
Suitable for: All units with control configuration KaControl C1
Suitable for: All units with control configuration KaControl C1
Article no.:
196003210006
KaController
with side operating keys, 24 V, wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9010 pure white, made of resistant PVC, Type 3210002
Suitable for: All units with control configuration KaControl C1
Suitable for: All units with control configuration KaControl C1
Article no.:
196003210002
Industry KaController
industrial housing with hinged transparent cover, lockable, with side operating keys, Surface-mounted, Protection class IP 65, Colour grey, made of plastic, Type 3214002
Suitable for: All units with control configuration KaControl C1, ProtecTor Door Air Curtains
Suitable for: All units with control configuration KaControl C1, ProtecTor Door Air Curtains
Article no.:
196003214002
room temperature sensor
Wall-mounted, Surface-mounted, Protection class IP 30, Colour similar to RAL 9010 pure white, made of plastic, Type 3250110
Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Article no.:
196003250110
Outside temperature sensor/industrial temperature sensor
Surface-mounted, Protection class IP 65, Colour similar to RAL 9010 pure white, Type 3250112
Suitable for: All units with control configuration KaControl C1, ProtecTor Door Air Curtains
Suitable for: All units with control configuration KaControl C1, ProtecTor Door Air Curtains
Article no.:
196003250112
Clip-on pipe sensor
to detect the medium temperature, Protection class IP 67, Temperature setting range -20 - 70 °C, Colour black, Type 3250115
Is there a risk of frost, e.g. due to the ingress of cold air – if so, then a KaControl clip-on pipe sensor should be chosen for each unit!
heating/cooling changeover function only in conjunction with 3-way valve!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Is there a risk of frost, e.g. due to the ingress of cold air – if so, then a KaControl clip-on pipe sensor should be chosen for each unit!
heating/cooling changeover function only in conjunction with 3-way valve!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Article no.:
196003250115
KaControl Tableau SEL4.0
with touch terminal, to monitor and control up to 60 Kampmann secondary air units (maximum 25 groups, maximum 6 units per group), 230 V AC, 30 W, Wall-mounted, Protection class IP 54, Colour RAL 7035 grey, Type 3232223
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101
Article no.:
196003232223
Serial KNX card
for integration into a KNX/EIB network, interface PCOS00KXN0, Type 3260702
The communication card slots into the free interface on the PCB.
Suitable for: All units with control configuration KaControl C1
The communication card slots into the free interface on the PCB.
Suitable for: All units with control configuration KaControl C1
Article no.:
196003260702
Serial CANbus card
to increase the number of units in a single-circuit system from 7 to a maximum of 30 units, one required per unit, Extension of the cable length from the first to the last unit from 30 m to 500 m, Can only be used with the KaControl -C1 control version!The room temperature cannot be recorded by a room sensor when using CanBus cards., Type 3260301
Suitable for: All units with control configuration KaControl C1
Suitable for: All units with control configuration KaControl C1
Article no.:
196003260301
Serial Modbus card
Type 3260101
Required for each device for connection to KaControl panels or on-site Modbus networks.
The communication card slots into the free interface on the PCB.
Suitable for: All units with control configuration KaControl C1
Required for each device for connection to KaControl panels or on-site Modbus networks.
The communication card slots into the free interface on the PCB.
Suitable for: All units with control configuration KaControl C1
Article no.:
196003260101
KaControl visualisation
for the central monitoring and control of air handling units, Type 3210701
The KaControl visualisation unit is used to monitor and control individual control zones and secondary air units for 4-pipe heating/cooling, 2-pipe heating or 2-pipe cooling.
The central interface for monitoring Kampmann products provides optimum assistance with technical monitoring.
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101, 100 Units
The KaControl visualisation unit is used to monitor and control individual control zones and secondary air units for 4-pipe heating/cooling, 2-pipe heating or 2-pipe cooling.
The central interface for monitoring Kampmann products provides optimum assistance with technical monitoring.
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101, 100 Units
Article no.:
196003210701
KaControl visualisation
for the central monitoring and control of air handling units, Type 3210702
The KaControl visualisation unit is used to monitor and control individual control zones and secondary air units for 4-pipe heating/cooling, 2-pipe heating or 2-pipe cooling.
The central interface for monitoring Kampmann products provides optimum assistance with technical monitoring.
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101, 300 Units
The KaControl visualisation unit is used to monitor and control individual control zones and secondary air units for 4-pipe heating/cooling, 2-pipe heating or 2-pipe cooling.
The central interface for monitoring Kampmann products provides optimum assistance with technical monitoring.
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101, 300 Units
Article no.:
196003210702
Switching and control units – Mixed air / fresh air, electro-mechanical
Servomotor
can be reversed, 230 V Open/Closed, Protection class IP 54, Type 30262
Suitable for: KaMAX
Suitable for: KaMAX
Article no.:
196000030262
Valve kits
2-way valve kit
as a straight valve body, Connection 1'', kvs value 3.3 m³/h, Type 31911
Suitable for: all unit heaters
Suitable for: all unit heaters
Article no.:
153000031911
Control shut-off valve
for automatic flow and temperature control, Connection 1'', kvs value 3.1 m³/h, Type 31950
Suitable for: Model size 4 - 5, TOP or Ultra Unit Heaters, Min. Flow volume 250 l/h, max. Flow volume 1800 l/h, DN 20
Suitable for: Model size 4 - 5, TOP or Ultra Unit Heaters, Min. Flow volume 250 l/h, max. Flow volume 1800 l/h, DN 20
Article no.:
153000031950
Control shut-off valve
for automatic flow and temperature control, Connection 1'', kvs value 4.1 m³/h, Type 31951
Suitable for: Model size 4 - 6, TOP or Ultra Unit Heaters, Min. Flow volume 400 l/h, max. Flow volume 2500 l/h, DN 25
Suitable for: Model size 4 - 6, TOP or Ultra Unit Heaters, Min. Flow volume 400 l/h, max. Flow volume 2500 l/h, DN 25
Article no.:
153000031951
Valve actuators, supplied loose
Valve actuator kit
Drive T, 24 V AC/DC, 2-point, normally closed, 3m connecting line-AEH, PVC, VA10N, 1 W, Protection class III, Protection class IP 54, Cable length 0.12 m, supplied separately, made of Polyamide
Suitable for: All units with electro-mechanical control configuration KaControl C1 in conjunction with 2-way valve or differential pressure-independent valve
Suitable for: All units with electro-mechanical control configuration KaControl C1 in conjunction with 2-way valve or differential pressure-independent valve
Article no.:
1960TS3P04050010B
Valves
Unit heater shut-off set, angled version
Connection 1'', Max. operating pressure 10 bar, Type 35976
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000035976
Unit heater shut-off set, straight version
Connection 1'', Max. operating pressure 10 bar, Type 35977
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000035977
Air outlets
calculation-relevant accessory
KaMAX
calculation-relevant accessory
Multi Air MiX for ceiling-mounted units, manual level adjustment
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000035111
KaMAX Open-Stop-Close switch
for electrically actuated continuously variable manual adjustment of the KaMAX louvre
Article no.:
196000030115
Louvre
two-row for wall- and ceiling-mounted units
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000035002
Induction air outlet louvre
calculation-relevant accessory
mainly used for wall-mounted units, for ceiling-mounted units with ceiling heights of more than 4.0 m
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000035101
Diffuser
calculation-relevant accessory
in four directions, for ceiling-mounted units
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000035004
Outlet nozzle
calculation-relevant accessory
for ceiling-mounted units, especially for high-ceilinged buildings, sendzimir galvanised
Suitable for: Model size 5
Suitable for: Model size 5
Article no.:
198000035006
Brackets
Universal 2-point brackets
recirculating air only, 1 complete set
Suitable for: Model size 4 - 7
Suitable for: Model size 4 - 7
Article no.:
198000030041
Universal 4-point brackets
recirculating air only, made of sendzimir galvanised sheet steel, as a 4-point fixing for ceiling installation, 1 complete set
Suitable for: Model size 4 - 7
Suitable for: Model size 4 - 7
Article no.:
198000030042
Universal 2-point T-support brackets
recirculating air only, Ceiling-mounted
Suitable for: Model size 4 - 7
Suitable for: Model size 4 - 7
Article no.:
198000030047
Wall brackets
recirculating air only, made of sendzimir galvanised sheet steel for wall mounting, a complete set
TIP and TOP unit heaters can be installed standing and also suspended.
price for 1 complete set
Suitable for: Model size 5
TIP and TOP unit heaters can be installed standing and also suspended.
price for 1 complete set
Suitable for: Model size 5
Article no.:
198000035044
Ceiling-wall brackets
for ceiling or wall mounting, consisting of 2 multi-edged brackets with slotted holes and screws
price for 1 complete set
Suitable for: Model size 5
price for 1 complete set
Suitable for: Model size 5
Article no.:
198000035049
Downloads
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(194 kB)
Certificate ISO 9001:2008
PDF
(118 kB)
UKCA Declaration Unit Heater
PDF
(450 kB)
ErP Data Sheet for TOP unit heaters
PDF
(234 kB)
Cross-product information
Products
PDF
(10.7 MB)
Technical catalogues
KaControl MC - Multi Connect
PDF
(2.2 MB)
TOP unit heaters
PDF
(18.7 MB)
Manuals
KaControl MC - Multi Connect
PDF
(1.3 MB)
TOP unit heaters
PDF
(7.7 MB)
TOP unit heaters, brief instructions
PDF
(4.1 MB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
CAD-Drawings
TOP unit heater, model 4 - 7, copper/aluminium heat exchanger [inch]
PDF
(294 kB)
TOP unit heater, size 4 - 7, copper/aluminium heat exchanger [mm]
PDF
(342 kB)
TOP unit heater, model 4 - 7, copper/aluminium heat exchanger [inch]
DWG
(1.4 MB)
TOP unit heater, size 4 - 7, copper/aluminium heat exchanger [mm]
DWG
(2.2 MB)
TOP unit heater, model 4 - 7, copper/aluminium heat exchanger [inch]
DXF
(10.8 MB)
TOP unit heater, size 4 - 7, copper/aluminium heat exchanger [mm]
DXF