Trench Technology
                                                                    
                                                                                                            Katherm HK
                                    Article no.: 
                                    14332431115524
                                
                                                            Overview
- Energy-saving, with flow-optimised impellers, cascaded arrangement as a continuous fan belt
- Easily removeable, plug & play fan
- Even air flow through convector
- Robust and whisper-quiet motor design
- Continuously variable control via external 0-10 V signal
- With anti-torsion device
- Made of the proven copper/aluminium combination, optimised for air flow and output
- Optionally available with projecting connections
- Painted graphite-grey
- Act as a finger guard for the tangential fan
- Filter frame, airflow baffle, grille seat and reinforcing stay to strengthen the trench
- Easy removal of tangential fan without tool
- Novl coupling/cone pin system
- Simultaneous sound decoupling
- For fast and safe wiring, saves installation time
- All factory-fitted components are wired to terminals
- Compact connecting terminal strip
- Convenient/space-saving connection area
- Power supply via on-site power supply components
- Control by Kampmann room thermostats or on-site controls
Calculate performance data
Sound power octave spectrum
                    The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
                        Oktave Spektrum
                    EPD data
                    Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary
                        | A | B | C | D | |
|---|---|---|---|---|
| GWP - Total kg CO2 eq | 2.18E+02 | 1.66E+01 | 8.51E+00 | -9.79E+01 | 
| GWP - fossil kg CO2 eq | 2.22E+02 | 1.48E+01 | 8.51E+00 | -9.69E+01 | 
| GWP - Biogenic kg CO2 eq | -6.45E+00 | 1.73E+00 | 3.35E-03 | -4.71E-02 | 
| GWP - Luluc kg CO2 eq | 2.22E+00 | 5.72E-02 | 4.17E-04 | -7.03E-01 | 
| ODP kg CFC-11 eq | 1.81E-05 | 1.00E-06 | 1.67E-07 | -6.53E-06 | 
| AP mol H+ eq | 2.43E+00 | 1.20E-01 | 3.46E-03 | -1.42E+00 | 
| EP - fresh water kg P eq | 2.13E-01 | 1.02E-02 | 1.10E-04 | -1.18E-01 | 
| EP - marine kg P eq | 2.55E-01 | 1.40E-02 | 1.17E-03 | -1.21E-01 | 
| EP - country mol N eq | 2.77E+00 | 1.66E-01 | 1.35E-02 | -1.41E+00 | 
| POCP kg NMVOC | 8.07E-01 | 4.16E-02 | 2.95E-03 | -4.07E-01 | 
| ADPE kg Sb eq | 3.38E-02 | 3.40E-03 | 2.64E-06 | -2.69E-02 | 
| ADPF MJ | 2.99E+03 | 3.67E+02 | 8.67E+00 | -1.19E+03 | 
| WDP m³ depriv. | 5.77E+01 | 2.37E+00 | 2.66E-01 | -2.10E+01 | 
| GWP-GHG kg CO2 eq | 2.17E+02 | 1.47E+01 | 8.50E+00 | -9.42E+01 | 
| PM disease inc. | 1.63E-05 | 4.33E-07 | 5.27E-08 | -7.37E-06 | 
| IR kBq U-235 eq | 3.35E+01 | 1.21E+01 | 5.05E-02 | -1.03E+01 | 
| ETP - FW CTUe | 1.55E+04 | 8.07E+02 | 3.55E+01 | -1.04E+04 | 
| HTP - C CTUh | 1.09E-06 | 2.82E-08 | 1.12E-09 | -5.52E-07 | 
| HTP - NC CTUh | 2.46E-05 | 1.17E-06 | 1.80E-08 | -1.62E-05 | 
| SQP - | 1.73E+03 | 1.62E+02 | 1.23E+01 | -5.69E+02 | 
| PERE MJ | 8.23E+02 | 6.80E+01 | 2.83E-01 | -2.29E+02 | 
| PERM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| PERT MJ | 8.23E+02 | 6.80E+01 | 2.83E-01 | -2.29E+02 | 
| PENRE MJ | 2.99E+03 | 3.67E+02 | 8.67E+00 | -1.19E+03 | 
| PENRM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| PENRT MJ | 2.99E+03 | 3.67E+02 | 8.67E+00 | -1.19E+03 | 
| SM kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| RSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| NRSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| FW m³ | 1.42E+00 | 1.48E-01 | 1.09E-02 | -6.63E-01 | 
| HWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| NHWD kg | 1.19E+01 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| RWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| CRU kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| MFR kg | 0.00E+00 | 0.00E+00 | 3.60E+01 | 0.00E+00 | 
| MER kg | 0.00E+00 | 0.00E+00 | 2.84E+00 | 0.00E+00 | 
| EE (Electrical) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
| EE (Thermal) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 | 
Accessories
Control accessories electromechanical 24 V
                            
            Clock thermostat
                        Heating/Cooling, 2- and 4-pipe, continuously variable, with LCD operating menu and integrated timer program, heating/cooling changeover by means of external potential-free contact (low voltage), 24 V Actuator, Open/Closed, 1 W, flush-mounted, Protection class IP 30, Colour similar to RAL 9010 pure white, Type 30456
Only in conjunction with valves/valve kits!
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
                        
Suitable for: EC units, electromechanical 24 V/230 V, 5 Katherm HK, Katherm HK 320 E, Katherm QK or Katherm QK nano Trench Technology, 5 PowerKon nano Perimeter Heating
            Only in conjunction with valves/valve kits!
optional connectible, remote sensor art. no. 196000148921
can optionally be connected, clip-on sensor art. no. 196000148922
Suitable for: EC units, electromechanical 24 V/230 V, 5 Katherm HK, Katherm HK 320 E, Katherm QK or Katherm QK nano Trench Technology, 5 PowerKon nano Perimeter Heating
                        Article no.: 
                        196000030456
                    
                    power supply unit
                        for external installation outside the trench heater, 86 - 264 V AC, 24 V DC, 47 Hz, 60 W, on DIN rail, Protection class II
                        
                        
Suitable for: EC units, electromechanical 24 V, 2 Katherm QK Trench Technology, 5 Katherm QK nano Trench Technology, 6 PowerKon nano Perimeter Heating
            Suitable for: EC units, electromechanical 24 V, 2 Katherm QK Trench Technology, 5 Katherm QK nano Trench Technology, 6 PowerKon nano Perimeter Heating
                        Article no.: 
                        196901338401
                    
                    power supply unit
                        for external installation outside the trench heater, 86 - 264 V AC, 24 V DC, 47 Hz, 92 W, on DIN rail, Protection class II
                        
                        
Suitable for: EC units, electromechanical 24 V, 4 Katherm QK Trench Technology, 7 Katherm QK nano Trench Technology, 10 PowerKon nano Perimeter Heating
            Suitable for: EC units, electromechanical 24 V, 4 Katherm QK Trench Technology, 7 Katherm QK nano Trench Technology, 10 PowerKon nano Perimeter Heating
                        Article no.: 
                        196901338402
                    
                    Valve kits
                            
            Differential pressure-independent valve kit
                        4-pipe, includes 2 differential pressure-independent axial valves, 2 return shut-off valves, angled and straight, 4 flexible stainless steel corrugated pipes, 1 elbow, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
                        
                        
Suitable for: Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
            Suitable for: Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
                        Article no.: 
                        194001433540
                    
                    Pre-settable valve kit
                        4-pipe, includes 2 pre-settable axial valves, 2 return shut-off valves, angled and straight, 4 flexible stainless steel corrugated pipes, 1 elbow, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
                        
                        
Suitable for: Katherm HK, max. Flow volume 920 l/h, DN 15
            Suitable for: Katherm HK, max. Flow volume 920 l/h, DN 15
                        Article no.: 
                        194001433740
                    
                    Pre-settable valve kit
                        4-pipe, includes 2 pre-settable axial valves, 2 return shut-off valves, angled and straight, 4 flexible stainless steel corrugated pipes, 1 elbow, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
                        
                        
Suitable for: Katherm HK, max. Flow volume 260 l/h, DN 15
            Suitable for: Katherm HK, max. Flow volume 260 l/h, DN 15
                        Article no.: 
                        194001433140
                    
                    Valve actuators, supplied loose
                            
            valve actuator
                        Drive T, 24 V AC/DC, 2-point, normally closed, 0.5m  connecting line-AEH, PVC, VA10N, 1 W, Protection class III, Protection class IP 54 Cable length 0.12 m, supplied separately, made of Polyamide
                        
                        
Suitable for: All units with electro-mechanical control configuration KaControl C1 in conjunction with 2-way valve or differential pressure-independent valve
            Suitable for: All units with electro-mechanical control configuration KaControl C1 in conjunction with 2-way valve or differential pressure-independent valve
                        Article no.: 
                        196TS0P040500AB
                    
                    Valves and return shut-off valves
                            
            Pre-settable thermostatic valve
                        Axial, pre-settable, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
                        
                        
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 260 l/h, DN 15
            Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 260 l/h, DN 15
                        Article no.: 
                        194000346911
                    
                    Pre-settable thermostatic valve
                        Axial, pre-settable, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
                        
                        
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 920 l/h, DN 15
            Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 920 l/h, DN 15
                        Article no.: 
                        194000346914
                    
                    Pre-setting key
                        Once per project necessary.
                        
                        
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
            Suitable for: pre-settable valve bodies, valve kits and convector connection kit
                        Article no.: 
                        194000346915
                    
                    Pre-setting set
                        Once per project necessary.
                        
                        
Suitable for: pre-settable valve bodies and valve kits with higher flow from 250 l/h
            Suitable for: pre-settable valve bodies and valve kits with higher flow from 250 l/h
                        Article no.: 
                        194000346916
                    
                    Return shut-off valve
                        2- and 4-pipe, Straight, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
                        
                        
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 610 l/h, DN 15
            Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 610 l/h, DN 15
                        Article no.: 
                        194000145952
                    
                    Return shut-off valve
                        2- and 4-pipe, angled, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
                        
                        
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 610 l/h, DN 15
            Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 610 l/h, DN 15
                        Article no.: 
                        194000145953
                    
                    Return shut-off valve
                        2- and 4-pipe, Straight, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
                        
                        
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 920 l/h, DN 15
            Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 920 l/h, DN 15
                        Article no.: 
                        194000145954
                    
                    Return shut-off valve
                        2- and 4-pipe, angled, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
                        
                        
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 920 l/h, DN 15
            Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 920 l/h, DN 15
                        Article no.: 
                        194000145955
                    
                    Differential pressure-independent thermostatic valve
                        Axial shape, differential pressure-dependent, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
                        
                        
Suitable for: Katherm NK, Katherm QK or Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
            Suitable for: Katherm NK, Katherm QK or Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
                        Article no.: 
                        194000347914
                    
                    Differential pressure-independent thermostatic valve
                        Straight, differential pressure-independent, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
                        
                        
Suitable for: Katherm NK, Katherm QK or Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
            Suitable for: Katherm NK, Katherm QK or Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
                        Article no.: 
                        194000347913
                    
                    Filter
                            
            Filter for air inlet
                        2- and 4-pipe, Replacement filter without frame, ISO Coarse 30% filter (G2)
                        
                        
Suitable for: Katherm HK 245 or Katherm HK 320, Length 3000 mm
            Suitable for: Katherm HK 245 or Katherm HK 320, Length 3000 mm
                        Article no.: 
                        143014313055
                    
                    Condensate tray/pump
                            
            Connection kit for condensation pump
                        230 V 50 Hz, 20 W, Protection class II, supplied separately
                        
                        
Suitable for: Katherm HK 320 or Katherm HK 360
            Suitable for: Katherm HK 320 or Katherm HK 360
                        Article no.: 
                        194000143813
                    
                    Connection kit for condensation pump
                        230 V 50 Hz, 20 W, Protection class II, factory-fitted
                        
                        
Suitable for: Katherm HK, Width 320 mm and 360 mm
            Suitable for: Katherm HK, Width 320 mm and 360 mm
                        Article no.: 
                        194000143814
                    
                    fitting kit for natural condensate drain
                        supplied separately
                        
                        
Suitable for: Katherm HK
            Suitable for: Katherm HK
                        Article no.: 
                        194000143817
                    
                    fitting kit for natural condensate drain
                        factory-fitted
                        
                        
Suitable for: Katherm HK
            Suitable for: Katherm HK
                        Article no.: 
                        194000143818
                    
                    Installation covers
                            
            Installation cover
                        to protect trench during installation, factory-fitted, grilles are packed separately
price per m
                        
Suitable for: Katherm HK 320
            price per m
Suitable for: Katherm HK 320
                        Article no.: 
                        194000100320
                    
                    Downloads
Declarations/Certificates
                Certificate ISO 9001, 14001, 50001
                                
                                    PDF
                                                                            (116 kB)
                                                                    
                                
                            Digital EPD database Katherm HK E
                                Digital EPD database Katherm HK
                                EPD Katherm HK E
                                
                                    PDF
                                                                            (1.6 MB)
                                                                    
                                
                            EPD Katherm HK
                                
                                    PDF
                                                                            (2.5 MB)
                                                                    
                                
                            UKCA Declaration Katherm HK, QK, QK nano
                                
                                    PDF
                                                                            (468 kB)
                                                                    
                                
                            further product information
                Products
                                
                                    PDF
                                                                            (10.7 MB)
                                                                    
                                
                            Information sheet trench heating BS EN 16430 UK version
                                
                                    PDF
                                                                            (215 kB)
                                                                    
                                
                            Manuals
                KaControl MC - Multi Connect
                                
                                    PDF
                                                                            (1.3 MB)
                                                                    
                                
                            Katherm HK 160/290, quick guide
                                
                                    PDF
                                                                            (3.8 MB)
                                                                    
                                
                            Katherm HK trench heating
                                
                                    PDF
                                                                            (7.7 MB)
                                                                    
                                
                            Technical catalogues
                Katherm HK trench heating
                                
                                    PDF
                                                                            (18 MB)
                                                                    
                                
                            KaControl MC - Multi Connect
                                
                                    PDF
                                                                            (2.2 MB)
                                                                    
                                
                            Katherm HK trench heating
                                
                                    PDF
                                                                            (13.1 MB)
                                                                    
                                
                            BIM data (Building Information Modeling)
                Kampmann Group BIM data
                                CAD-Drawings
                Katherm HK, trench width 320 mm, 4-pipe system, views
                                
                                    PDF
                                                                            (145 kB)
                                                                    
                                
                            Katherm HK, trench width 320 mm, 4-pipe system, top views
                                
                                    PDF
                                                                            (100 kB)
                                                                    
                                
                            Katherm HK, trench width 320 mm, 4-pipe system, views
                                
                                    DXF
                                                                            (2.7 MB)
                                                                    
                                
                            Katherm HK, trench width 320 mm, 4-pipe system, views
                                
                                    DWG
                                                                            (731 kB)
                                                                    
                                
                            Katherm HK, trench width 320 mm, 4-pipe system, top views
                                
                                    DXF
                                                                            (4.5 MB)
                                                                    
                                
                            Katherm HK, trench width 320 mm, 4-pipe system, top views
                                
                                    DWG
                                                                            (1.1 MB)
                                                                    
                                
                            