Trench Technology
Katherm HK
Article no.:
143324313113C1
Overview
- KaControl control system for operation via a separate room control unit, external control via a 0-10 V signal or building automation systems, such as KNX, modbus, BACnet (additional plug-in card accessory required)
- Room control of up to six units or up to 30 units with CANbus cards that are additionally required
- Demand-led automatic fan or optional manual fan control
- Connection options, including external room sensor, window contact etc.
- Individually parametrisable for optimum adaptation to the situation on site
- Energy-saving, with flow-optimised impellers, cascaded arrangement as a continuous fan belt
- Easily removeable, plug & play fan
- Even air flow through convector
- Robust and whisper-quiet motor design
- Continuously variable control via external 0-10 V signal
The KaControl control option provides the option of omitting the valve control data point when externally controlled by an on-site 0-10 V signal. The fan valve and speed control logic comes from the KaControl. Note the deviation of the signal points from the design program with 0-10 V control by others.
Design program data: 2 V 4 V 6 V 8 V 10 V
External 0-10 V on the KaControl: 4.3 V 5.5 V 6.8 V 7.8 V 10 V
- With anti-torsion device
- Made of the proven copper/aluminium combination, optimised for air flow and output
- Optionally available with projecting connections
- Painted graphite-grey
- Act as a finger guard for the tangential fan
- Filter frame, airflow baffle, grille seat and reinforcing stay to strengthen the trench
- Easy removal of tangential fan without tool
- Novl coupling/cone pin system
- Simultaneous sound decoupling
- For fast and safe wiring, saves installation time
Calculate performance data
Sound power octave spectrum
The sound power is determined depending on the use according to DIN EN ISO 3741 (in the echo chamber), according to DIN EN ISO 3744 (in the low-reflective half-space) or according to DIN EN ISO 9614 (intensity method).
Oktave Spektrum
EPD data
Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary
A | B | C | D | |
---|---|---|---|---|
GWP - Total kg CO2 eq | 7.47E+01 | 5.36E+00 | 2.74E+00 | -3.16E+01 |
GWP - fossil kg CO2 eq | 7.63E+01 | 4.78E+00 | 2.74E+00 | -3.12E+01 |
GWP - Biogenic kg CO2 eq | -1.94E+00 | 5.59E-01 | 1.08E-03 | -1.52E-02 |
GWP - Luluc kg CO2 eq | 3.34E-01 | 1.84E-02 | 1.34E-04 | -2.27E-01 |
ODP kg CFC-11 eq | 4.28E-06 | 3.23E-07 | 5.39E-08 | -2.10E-06 |
AP mol H+ eq | 7.98E-01 | 3.87E-02 | 1.12E-03 | -4.58E-01 |
EP - fresh water kg P eq | 6.67E-02 | 3.29E-03 | 3.53E-05 | -3.80E-02 |
EP - marine kg P eq | 8.91E-02 | 4.53E-03 | 3.78E-04 | -3.91E-02 |
EP - country mol N eq | 9.85E-01 | 5.35E-02 | 4.34E-03 | -4.54E-01 |
POCP kg NMVOC | 2.92E-01 | 1.34E-02 | 9.53E-04 | -1.31E-01 |
ADPE kg Sb eq | 1.15E-02 | 1.10E-03 | 8.51E-07 | -8.68E-03 |
ADPF MJ | 9.54E+02 | 1.18E+02 | 2.79E+00 | -3.85E+02 |
WDP m³ depriv. | 2.19E+01 | 7.63E-01 | 8.57E-02 | -6.77E+00 |
GWP-GHG kg CO2 eq | 7.50E+01 | 4.74E+00 | 2.74E+00 | -3.04E+01 |
PM disease inc. | 5.86E-06 | 1.40E-07 | 1.70E-08 | -2.38E-06 |
IR kBq U-235 eq | 7.90E+00 | 3.91E+00 | 1.63E-02 | -3.33E+00 |
ETP - FW CTUe | 4.79E+03 | 2.60E+02 | 1.14E+01 | -3.35E+03 |
HTP - C CTUh | 4.46E-07 | 9.10E-09 | 3.62E-10 | -1.78E-07 |
HTP - NC CTUh | 7.73E-06 | 3.77E-07 | 5.81E-09 | -5.23E-06 |
SQP - | 6.45E+02 | 5.24E+01 | 3.98E+00 | -1.83E+02 |
PERE MJ | 2.22E+02 | 2.19E+01 | 9.11E-02 | -7.38E+01 |
PERM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT MJ | 2.22E+02 | 2.19E+01 | 9.11E-02 | -7.38E+01 |
PENRE MJ | 9.54E+02 | 1.18E+02 | 2.79E+00 | -3.85E+02 |
PENRM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT MJ | 9.54E+02 | 1.18E+02 | 2.79E+00 | -3.85E+02 |
SM kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW m³ | 4.57E-01 | 4.77E-02 | 3.52E-03 | -2.14E-01 |
HWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD kg | 3.83E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR kg | 0.00E+00 | 0.00E+00 | 1.16E+01 | 0.00E+00 |
MER kg | 0.00E+00 | 0.00E+00 | 9.16E-01 | 0.00E+00 |
EE (Electrical) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Accessories
Control accessories KaControl
KaController
with one-button operation, 24 V, wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9010 pure white, made of resistant PVC, Type 3210001
Suitable for: All units with control configuration KaControl C1
Suitable for: All units with control configuration KaControl C1
Article no.:
196003210001
KaController
with one-button operation, 24 V, wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9017 traffic black, made of resistant PVC, Type 3210006
Suitable for: All units with control configuration KaControl C1
Suitable for: All units with control configuration KaControl C1
Article no.:
196003210006
KaController
with side operating keys, 24 V, wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9010 pure white, made of resistant PVC, Type 3210002
Suitable for: All units with control configuration KaControl C1
Suitable for: All units with control configuration KaControl C1
Article no.:
196003210002
room temperature sensor
Wall-mounted, Surface-mounted, Protection class IP 30, Colour similar to RAL 9010 pure white, made of plastic, Type 3250110
Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Article no.:
196003250110
Clip-on pipe sensor
to detect the medium temperature, Protection class IP 67, Temperature setting range -20 - 70 °C, Colour black, Type 3250115
Is there a risk of frost, e.g. due to the ingress of cold air – if so, then a KaControl clip-on pipe sensor should be chosen for each unit!
heating/cooling changeover function only in conjunction with 3-way valve!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Is there a risk of frost, e.g. due to the ingress of cold air – if so, then a KaControl clip-on pipe sensor should be chosen for each unit!
heating/cooling changeover function only in conjunction with 3-way valve!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Article no.:
196003250115
KaControl Tableau SEL4.0
with touch terminal, to monitor and control up to 60 Kampmann secondary air units (maximum 25 groups, maximum 6 units per group), 230 V AC, 30 W, Wall-mounted, Protection class IP 54, Colour RAL 7035 grey, Type 3232223
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101
Article no.:
196003232223
Serial KNX card
for integration into a KNX/EIB network, interface PCOS00KXN0, Type 3260702
The communication card slots into the free interface on the PCB.
Suitable for: All units with control configuration KaControl C1
The communication card slots into the free interface on the PCB.
Suitable for: All units with control configuration KaControl C1
Article no.:
196003260702
Serial CANbus card
to increase the number of units in a single-circuit system from 7 to a maximum of 30 units, one required per unit, Extension of the cable length from the first to the last unit from 30 m to 500 m, Can only be used with the KaControl -C1 control version!The room temperature cannot be recorded by a room sensor when using CanBus cards., Type 3260301
Suitable for: All units with control configuration KaControl C1
Suitable for: All units with control configuration KaControl C1
Article no.:
196003260301
Serial Modbus card
Type 3260101
Required for each device for connection to KaControl panels or on-site Modbus networks.
The communication card slots into the free interface on the PCB.
Suitable for: All units with control configuration KaControl C1
Required for each device for connection to KaControl panels or on-site Modbus networks.
The communication card slots into the free interface on the PCB.
Suitable for: All units with control configuration KaControl C1
Article no.:
196003260101
KaControl visualisation
for the central monitoring and control of air handling units, Type 3210701
The KaControl visualisation unit is used to monitor and control individual control zones and secondary air units for 4-pipe heating/cooling, 2-pipe heating or 2-pipe cooling.
The central interface for monitoring Kampmann products provides optimum assistance with technical monitoring.
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101, 100, Units
The KaControl visualisation unit is used to monitor and control individual control zones and secondary air units for 4-pipe heating/cooling, 2-pipe heating or 2-pipe cooling.
The central interface for monitoring Kampmann products provides optimum assistance with technical monitoring.
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101, 100, Units
Article no.:
196003210701
KaControl visualisation
for the central monitoring and control of air handling units, Type 3210702
The KaControl visualisation unit is used to monitor and control individual control zones and secondary air units for 4-pipe heating/cooling, 2-pipe heating or 2-pipe cooling.
The central interface for monitoring Kampmann products provides optimum assistance with technical monitoring.
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101, 300, Units
The KaControl visualisation unit is used to monitor and control individual control zones and secondary air units for 4-pipe heating/cooling, 2-pipe heating or 2-pipe cooling.
The central interface for monitoring Kampmann products provides optimum assistance with technical monitoring.
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101, 300, Units
Article no.:
196003210702
Valve kits
4-pipe, Connection 1/2'', Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Suitable for: Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Article no.:
194001433540
4-pipe, Includes 2x pre-settable valves, axial, 2x return shut-off valves, angled and straight, 4x flexible stainless steel corrugated pipes, 1x bracket on the heating side
, Connection 1/2'', Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm HK, max. Flow volume 920 l/h, DN 15
, Connection 1/2'', Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm HK, max. Flow volume 920 l/h, DN 15
Article no.:
194001433740
4-pipe, Includes 2x pre-settable valves, axial, 2x return shut-off valves, angled and straight, 4x flexible stainless steel corrugated pipes, 1x bracket on the heating side
, Connection 1/2'', Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm HK, max. Flow volume 260 l/h, DN 15
, Connection 1/2'', Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm HK, max. Flow volume 260 l/h, DN 15
Article no.:
194001433140
Valve actuators, supplied loose
valve actuator
Drive T, 24 V AC/DC, 2-point, normally closed, 0.5m connecting line-AEH, PVC, VA10N, 1 W, Protection class III, Protection class IP 54 Cable length 0.12 m, supplied separately, made of Polyamide
Suitable for: All units with electro-mechanical control configuration KaControl C1 in conjunction with 2-way valve or differential pressure-independent valve
Suitable for: All units with electro-mechanical control configuration KaControl C1 in conjunction with 2-way valve or differential pressure-independent valve
Article no.:
1960TS0P04050010B
Valves and return shut-off valves
Pre-adjustable valve kit
Axial, pre-settable, Connection 1/2'', Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK, Katherm HK, max. Flow volume 260 l/h, DN 15
Suitable for: Katherm NK, Katherm QK, Katherm HK, max. Flow volume 260 l/h, DN 15
Article no.:
194000346911
Pre-adjustable valve kit
Axial, pre-settable, Connection 1/2'', Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK, Katherm HK, max. Flow volume 920 l/h, DN 15
Suitable for: Katherm NK, Katherm QK, Katherm HK, max. Flow volume 920 l/h, DN 15
Article no.:
194000346914
Pre-setting key
Once per project necessary.
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Article no.:
194000346915
Pre-setting set
Once per project necessary.
Suitable for: pre-settable valve bodies and valve kits with higher flow from 250 l/h
Suitable for: pre-settable valve bodies and valve kits with higher flow from 250 l/h
Article no.:
194000346916
Return shut-off valve
2- and 4-pipe, Straight, Connection 1/2'', Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK, Katherm HK, max. Flow volume 610 l/h, DN 15
Suitable for: Katherm NK, Katherm QK, Katherm HK, max. Flow volume 610 l/h, DN 15
Article no.:
194000145952
Return shut-off valve
2- and 4-pipe, angled, Connection 1/2'', Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK, Katherm HK, max. Flow volume 610 l/h, DN 15
Suitable for: Katherm NK, Katherm QK, Katherm HK, max. Flow volume 610 l/h, DN 15
Article no.:
194000145953
Return shut-off valve
2- and 4-pipe, Straight, Connection 1/2'', Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK, Katherm HK, max. Flow volume 920 l/h, DN 15
Suitable for: Katherm NK, Katherm QK, Katherm HK, max. Flow volume 920 l/h, DN 15
Article no.:
194000145954
Return shut-off valve
2- and 4-pipe, angled, Connection 1/2'', Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK, Katherm HK, max. Flow volume 920 l/h, DN 15
Suitable for: Katherm NK, Katherm QK, Katherm HK, max. Flow volume 920 l/h, DN 15
Article no.:
194000145955
Differential pressure-independent valve kit
Connection 1/2'', Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK, Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Suitable for: Katherm NK, Katherm QK, Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Article no.:
194000347914
Differential pressure-independent valve kit
Connection 1/2'', Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK, Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Suitable for: Katherm NK, Katherm QK, Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Article no.:
194000347913
Filter
Filter for air inlet
2- and 4-pipe, Replacement filter without frame, ISO Coarse 30% filter (G2)
Suitable for: Length 915 mm
Suitable for: Length 915 mm
Article no.:
143014313013
Condensate tray/pump
Connection kit for condensation pump
230 V 50 Hz, 20 W, Protection class II, supplied separately
Article no.:
194000143813
Connection kit for condensation pump
230 V 50 Hz, 20 W, Protection class II, factory-fitted
Suitable for: Katherm HK, Width 320 mm and 360 mm
Suitable for: Katherm HK, Width 320 mm and 360 mm
Article no.:
194000143814
fitting kit for natural condensate drain
supplied separately
Suitable for: Katherm HK
Suitable for: Katherm HK
Article no.:
194000143817
fitting kit for natural condensate drain
factory-fitted
Suitable for: Katherm HK
Suitable for: Katherm HK
Article no.:
194000143818
Installation covers
Installation cover
to protect trench during installation, factory-fitted, grilles are packed separately
price per m
price per m
Article no.:
194000100320
Downloads
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(116 kB)
Digital EPD database Katherm HK E
Digital EPD database Katherm HK
EPD Katherm HK E
PDF
(1.6 MB)
EPD Katherm HK
PDF
(2.5 MB)
UKCA Declaration Katherm HK, QK, QK nano
PDF
(468 kB)
Cross-product information
Products
PDF
(10.7 MB)
Information sheet trench heating BS EN 16430 UK version
PDF
(215 kB)
Manuals
System Manual KaControl MC
PDF
(4.6 MB)
KaControl MC - Multi Connect
PDF
(1.3 MB)
Katherm HK trench heating
PDF
(7.7 MB)
Katherm HK, brief instructions
PDF
(3.8 MB)
Technical catalogues
KaControl MC - Multi Connect
PDF
(2.2 MB)
Katherm HK trench heating
PDF
(13.1 MB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
CAD-Drawings
Katherm HK, trench width 320 mm, 4-pipe system, views
PDF
(145 kB)
Katherm HK, trench width 320 mm, 4-pipe system, top views
PDF
(100 kB)
Katherm HK, trench width 320 mm, 4-pipe system, views
DXF
(2.7 MB)
Katherm HK, trench width 320 mm, 4-pipe system, views
DWG
(731 kB)
Katherm HK, trench width 320 mm, 4-pipe system, top views
DXF
(4.5 MB)
Katherm HK, trench width 320 mm, 4-pipe system, top views
DWG
(1.1 MB)