• United Kingdom English (United Kingdom)
  • Projects

Country and language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Magazine
  • Contact
      • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Katherm HK
          • Katherm QK
          • Katherm QK nano
          • Katherm NK
          • Katherm QL
          • Katherm QE
        • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
          • TIP
          • TOP
          • Ultra
          • Ultra Allround
          • TOP C
        • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Venkon
          • KaCool D AF
          • KaDius
          • KaDeck
          • PowerKon LT
          • Venkon XL
          • KaCool W
          • KaCool D HY
        • Heat pump radiatorsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Powerkon LT
        • Perimeter HeatingArrow Right 1 Streamline Icon: https://streamlinehq.com
          • PowerKon + F
          • PowerKon + W
          • PowerKon + ST
          • PowerKon nano
          • PowerKon QE
        • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • WZA
        • Air curtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • UniLine
          • Cassette UniLine
          • Tandem
          • Tandem - Cassette Version
          • ProtecTor
        • Design GrillesArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Optiline
          • Wooden grilles
      • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Download Center
        • Calculation programs
        • Air Volume Flow Calculator
      • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Customer Service
        • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Site Survey and Installation
        • SeminarsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • CPD Inhouse Seminars
          • CPD Webinars
      • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
        • The Kampmann UK Ltd.
        • Research and development
        • Sustainability
        • Compliance
      • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
        • News
        • Technology and knowledge
      • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Find Contact
        • Contact Form
      • Home
      • Products
      • Trench Technology
      • Katherm Qk

      Products

      • Trench Technology
      • Unit Heaters
      • Fan Coils
      • Heat pump radiators
      • Air curtains
      • Perimeter Heating
      • Decentralised Ventilation Units
      • Design Grilles

      Company

      • The Kampmann UK Ltd.
      • Research and Development
      • Sustainablility
      • Magazine

      Support

      • Project Support
      • Customer Service
      • Contact
      • Seminars

      Contact

      +44 1932 228592info@kampmann.co.uk
      • Imprint
      • General Terms and Conditions
      • Central Data Protection Instructions
      • Cookies
      • Reporting system
      • Modern Slavery Statement
      • Compliance

      Our products are intended exclusively for B2B sales.

      Katherm QK

      Article no.: 142421111115C1
      • Details
      • Description
      • Technical data
      • Acoustic data
      • EPD
      • Dimensions
      • Accessories
      • BIM
      • Downloads

      basic unit

      Kampmann Katherm QK trench heater, convector-based ready-to-install heating trenches for installation in the floor with tangential fan convection. Heat outputs tested in accordance with DIN EN 16430, parts 1 and 2.
      Trench chassis made of sendzimir galvanised sheet steel, coated in graphite gray. Height-adjustable mounting brackets on the sides with impact sound insulation; sturdy height adjustment mechanism with impact sound insulation. Includes cross braces to reinforce the trench chassis. With pre-punched connection openings for water supply and return as well as electrical connections, on the room side. With a frame edging profile color-matched to the grate. With standard protective cover and frame edge. With a cover plate over the connection area.
      Life Cycle Assessment (LCA) data is published in the form of an EPD according to EN 15804 and is available to download from the International EPD System. Registered in the building products platform DGNB Navigator. GWP (phase A1-A3), kg CO2 Äq.3,64E+01. Further calculations possible online.

      Heat exchanger

      High-performance heat exchanger made of circular copper pipes with aluminum fins and a Eurokonus valve connection, coated in graphite gray. With integral bleed option.
      System2-pipe
      Max. operating pressurebar10
      Max. entering water temperature°C95
      Min. entering water temperature°C15
      Max. air inlet temp.°C40

      Fan

      Tangential fan with safety guard. Energy-saving EC fan with 0-10 V signal for continuously variable speed control. All rotating parts are silent and mounted on maintenance-free bearings. Motor monitoring with internal fault processing. Factory-wired.

      Control

      KaControl SmartBoard control version
      Factory-fitted and wired electrical connection unit, including 230 V/24 V power supply unit.
      Operation via separate room control unit acting as a master unit or used as a slave unit in group mode, alternatively single unit control via an analogue 0-10 V signal, alternatively single unit control via communication cards.
      KaControl control PCB regulation and control functions:
      • room control of up to six units via a KaControl t-LAN interface
      • room control of up to 30 units and CANbus card additionally required
      • Temperature measurement optionally via sensor in the room control unit or external room temperature sensor
      • Slot for optional communication cards for integration into KNX TP or Modbus RTU automation networks
      • Two digital inputs, configurable e.g. device on/off
      • Comfort/Economy switch-over with invertible switching logic e.g. to detect window contact, presence alert or card reader message
      • Thre analogue inputs for room temperature sensor, contact temperature sensor, coil sensor
      • Two digital outputs for control of 1 heating valve / 1 cooling valve 24 V DC
      • error message 24 V DC, only with 2-pipe
      • valve activation via clip-on sensor temperature by media monitoring (optional)
      • room and unit frost protection control
      • offset function for temperature sensor
      • Demand-led automatic fan mode with constant (0-100 %) fan control
      • parameter-driven integration of natural convection into the control sequence
      • Sequential control of valve and fan via a 0-10 VDC point. Motor monitoring with fault signal processing on the KaControl control board factory-wired ready for connection.

      Grille

      With double T-profile grille. Connections made of corrosion-proof steel springs with matching spacers.

      Configuration

      Grille designRoll-up grille
      Grille finishAluminium, natural anodised
      Lengthmm1000
      Widthmm190
      Heightmm112
      Bar heightmm18
      Bar depthmm5
      Bar spacingmm9
      Free area, approx. %65
      Weightkg11.5

      Connection

      • left

      For higher room loads

      • For rooms with floor-to-ceiling windows
      • Fast heating with low noise level
      • for LPHW and heat pump operation
      • Simple installation and hydraulics connection
      • Continuous channel bands possible, adapted to facades
      • Ready-to-connect control systems and integration in BMS systems
      • Simple hydraulics connection via suitable valve sets
      • Primary air intake via connectable supply air ducts
      • Cover plates for privacy and protection against soiling
      • Extensive range of rolling and linear grilles with matching frames
      • Life cycle assessment data (EPD) available for building sustainability certification

      Slip joints possible

      • Detachable headpiece
      • for easy coupling of the trench convectors
      • for attaching dummy sections, miter corners, etc.

      EC fan

      • for uniform air flow through the convectors; thus high heat output with low noise emissions
      • Robust motor design
      • Stepless speed control via an external 0 - 10 V signal
      • Motor monitoring with internal fault processing

      KaControl smart room control

      • KaControl control system for operation via separate room control unit, external control via 0-10V signal or via building automation systems such as KNX, Modbus, BACnet (additional accessories plug-in card required)
      • Room group control of up to six units or up to 30 units via additionally required CanBus cards
      • Demand-dependent automatic fan control or optional manual fan control
      • Connection options e.g. external room sensor, window contact etc.
      • Individually parameterizable for optimum adaptation to the conditions on site

      Heat exchanger

      • Convectors made from proven copper / aluminum combination
      • Optimized for air flow and heat dissipation
      • graphite-grey coated

      KaControl control option with external 0-10 V control

      The KaControl control option provides the option of omitting the valve control data point when externally controlled by an on-site 0-10 V signal. The fan valve and speed control logic comes from the KaControl. Note the deviation of the signal points from the design program with 0-10 V control by others.

      Design program data: 2 V 4 V 6 V 8 V 10 V

      External 0-10 V on the KaControl: 4.3 V 5.5 V 6.8 V 7.8 V 10 V

      Eurokonus valve connection

      • for quick connection
      • Saves assembly time

      Robust height adjustment

      • Step-stable height adjustment for safe elevation of the trench convectors
      • with plastic cap for sound decoupling

      View

      • IFront view
      • IItop view (without cover panel)
      • IIICross-section, enlarged

      Further Information

      • 1window side
      • 2room side

      Specifications

      Article no.142421111115C1
      Height112 mm
      Width190 mm
      Length (A)1,000 mm
      finned length (B)430 mm
      Water content0.3 l
      Weight11.4 kg

      We consider the environmental impact of our products throughout their entire life cycle! The result is Environmental Product Declarations (EPDs). The EPDs can be easily submitted to all common building sustainability certification systems, such as DGNB, BREEAM, or LEED, and are available in the download area or directly here via the download button. In addition, the product is registered on the DGNB Navigator building products platform.

      Basic data

      Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
      GWP - Total
      Climate change - total
      kg CO2 eq3.54E+019.80E-017.90E-023.64E+011.30E+002.78E-011.35E-013.60E-025.81E-012.98E+000.00E+004.45E-021.46E+002.22E-02-1.82E+01
      GWP - fossil
      Climate change - fossil
      kg CO2 eq3.49E+019.80E-011.33E+003.72E+011.30E+002.76E-011.26E-013.18E-025.78E-012.61E+000.00E+004.44E-021.46E+002.20E-02-1.81E+01
      GWP - Biogenic
      Climate change - biogenic
      kg CO2 eq2.07E-012.37E-03-1.25E+00-1.05E+001.69E-032.39E-035.44E-03-3.17E-03-1.36E-033.62E-010.00E+001.07E-042.80E-042.22E-04-1.38E-02
      GWP - Luluc
      Climate change - land use and land use change
      kg CO2 eq3.59E-013.69E-041.17E-033.60E-012.11E-042.76E-042.48E-037.38E-034.84E-033.58E-030.00E+001.66E-054.02E-052.23E-05-1.50E-01
      ODP
      Ozone Depletion
      kg CFC-11 eq2.50E-062.45E-072.49E-082.77E-063.03E-071.18E-081.07E-082.99E-094.49E-081.77E-070.00E+001.11E-081.37E-086.68E-09-1.27E-06
      AP
      Acidification
      mol H+ eq4.03E-013.15E-039.58E-034.16E-016.48E-031.15E-035.17E-042.40E-041.78E-028.21E-030.00E+001.41E-043.12E-041.85E-04-2.19E-01
      EP - Freshwater
      Eutrophication aquatic freshwater
      kg P eq3.23E-026.37E-051.60E-033.40E-023.93E-058.36E-052.59E-051.09E-051.41E-034.18E-040.00E+002.88E-061.13E-056.38E-06-1.85E-02
      EP - Marine
      Eutrophication aquatic marine
      kg P eq7.90E-027.06E-041.44E-038.12E-022.21E-033.11E-041.36E-045.31E-055.00E-031.93E-030.00E+003.16E-051.22E-046.38E-05-2.04E-02
      EP - Terrestrial
      Eutrophication terrestrial
      mol N eq4.48E-017.68E-031.28E-024.68E-012.42E-022.32E-031.24E-033.53E-041.47E-022.14E-020.00E+003.46E-041.24E-036.95E-04-2.33E-01
      POCP
      Photochemical ozone formation
      kg NMVOC1.32E-011.97E-033.41E-031.38E-015.88E-036.26E-042.70E-041.11E-043.74E-034.91E-030.00E+008.82E-052.87E-041.71E-04-6.91E-02
      ADPE
      Depletion of abiotic resources - minerals and metals
      kg Sb eq4.96E-032.35E-061.49E-064.96E-031.24E-061.69E-068.21E-075.27E-073.90E-047.38E-060.00E+001.06E-073.25E-077.18E-08-3.52E-03
      ADPF
      Abiotic resource depletion - fossil fuels
      MJ4.71E+021.60E+011.48E+015.02E+021.91E+015.93E+003.00E+004.14E-017.68E+006.96E+010.00E+007.22E-013.48E-015.16E-01-2.26E+02
      WDP
      Water use
      m³ depriv.1.74E+015.33E-021.85E-011.76E+013.13E-023.56E-013.96E-021.79E-024.11E-019.35E-020.00E+002.41E-032.32E-022.24E-02-3.18E+00
      GWP-GHG
      Global Warming Potential total excl. biogenic carbon following IPCC AR5 methodology
      kg CO2 eq3.43E+019.73E-011.31E+003.66E+011.29E+002.68E-011.25E-013.80E-025.70E-012.59E+000.00E+004.40E-022.20E-021.46E+00-1.76E+01
      PM
      Particulate Matter emissions
      disease inc.2.17E-068.59E-083.03E-082.29E-064.31E-081.86E-083.50E-092.25E-096.05E-083.69E-080.00E+003.88E-092.34E-093.59E-09-1.31E-06
      IR
      Ionizing radiation, human health
      kBq U-235 eq4.04E+008.06E-025.01E-024.17E+008.97E-021.93E-028.97E-021.54E-031.61E-012.45E+000.00E+003.65E-033.19E-032.43E-03-2.09E+00
      ETP - FW
      Ecotoxicity (fresh water)
      CTUe2.34E+031.25E+011.79E+012.37E+031.19E+016.44E+002.48E+001.07E+001.53E+023.25E+010.00E+005.63E-015.68E+003.67E-01-1.54E+03
      HTP - C
      Human toxicity, cancer effects
      CTUh1.59E-073.40E-104.86E-101.60E-072.23E-102.82E-095.51E-115.46E-115.10E-096.57E-100.00E+001.54E-112.12E-101.58E-11-9.50E-08
      HTP - NC
      Human toxicity, non-cancer effects
      CTUh3.32E-061.31E-082.04E-083.35E-061.66E-081.41E-081.55E-091.24E-092.28E-071.87E-080.00E+005.91E-102.64E-092.45E-10-2.38E-06
      SQP
      Land use related impacts/Soil quality
      -1.97E+021.89E+018.44E+013.00E+029.20E+007.53E-011.39E+006.34E-011.12E+012.62E+010.00E+008.59E-011.17E-011.28E+00-8.82E+01

      Resource use

      Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
      PERE
      Use of renewable primary energy excluding resources used as raw materials
      MJ1.06E+022.03E-011.62E+011.23E+021.28E-012.07E-016.38E-011.00E-012.01E+001.27E+010.00E+009.20E-033.59E-028.82E-03-4.56E+01
      PERM
      Use of renewable primary energy resources used as raw materials
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      PERT
      Total use of renewable primary energy
      MJ1.06E+022.03E-011.62E+011.23E+021.28E-012.07E-016.38E-011.00E-012.01E+001.27E+010.00E+009.20E-033.59E-028.82E-03-4.56E+01
      PENRE
      Use of non-renewable primary energy excluding resources used as raw materials
      MJ4.71E+021.60E+011.48E+015.02E+021.91E+015.93E+003.01E+004.23E-017.68E+006.96E+010.00E+007.22E-013.48E-015.16E-01-2.26E+02
      PENRM
      Use of non-renewable primary energy resources used as raw materials
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      PENRT
      Total use of non-renewable primary energy
      MJ4.71E+021.60E+011.48E+015.02E+021.91E+015.93E+003.01E+004.23E-017.68E+006.96E+010.00E+007.22E-013.48E-015.16E-01-2.26E+02
      SM
      Secondary material
      kg3.27E-020.00E+000.00E+003.27E-020.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      RSF
      Renewable secondary fuels
      MJ2.22E-040.00E+000.00E+002.22E-040.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      NRSF
      Non-renewable secondary fuels
      MJ1.43E-020.00E+000.00E+001.43E-020.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      FW
      Net use of fresh water
      m³3.84E-013.26E-035.24E-033.93E-012.34E-036.96E-032.17E-035.40E-041.63E-021.67E-020.00E+001.47E-048.06E-045.82E-04-1.12E-01

      Waste & Output Flows

      Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
      HWD
      Hazardous waste disposed
      kg1.73E+000.00E+000.00E+001.73E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      NHWD
      Non-hazardous waste disposed
      kg1.12E+000.00E+002.17E+003.30E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      RWD
      Radioactive waste disposed
      kg1.43E-030.00E+000.00E+001.43E-030.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      CRU
      Components for reuse
      kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      MFR
      Material for recycling
      kg5.59E-040.00E+000.00E+005.59E-040.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+006.60E+000.00E+000.00E+00
      MER
      Materials for energy recovery
      kg2.46E-060.00E+000.00E+002.46E-060.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+005.40E-010.00E+000.00E+00
      EE (Electrical)
      Exported energy electrical
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      EE (Thermal)
      Exported energy thermal
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00