Katherm QK
Overview
• KaControl MC control system for operation via separate touch panel TP 2"
• Room group control of up to ten units via factory-fitted CAN-bus (up to 100 m)
• Demand-led automatic or optional manual fan control
• Freely configurable multifunctional inputs that can be used, for example, to detect temperatures, window contacts, presence detectors, card readers etc.
• Integrated Webserver (Wi-Fi or LAN) for ease of commissioning, parametrisation, trend data analysis etc. on a laptop or mobile device
The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.
- For fast connection
- Saves installation time
- Optional valves (accessories)
- For quick and safe electrical connection
- Saves installation time
- For control options: KaControl, -C1 and 230 V electromechanical --00
- Including 230/24 V power unit
- Removable end panel for ease of connection of trenches
- As visual cover and protection against dirt ingress
- A proven combination of copper/aluminium
- Optimised for air flow and heat dissipation
- Painted graphite-grey
Treated supply air can also be fed into the rooms through the Katherm supply air module (Length 400 mm).
Calculate performance data
A | B | C | D | |
---|---|---|---|---|
GWP - Total kg CO2 eq | 1.34E+02 | 8.10E+00 | 3.31E+00 | -3.96E+01 |
GWP - fossil kg CO2 eq | 1.35E+02 | 7.27E+00 | 3.31E+00 | -3.92E+01 |
GWP - Biogenic kg CO2 eq | -1.64E+00 | 7.87E-01 | 1.32E-03 | -3.00E-02 |
GWP - Luluc kg CO2 eq | 6.99E-01 | 3.97E-02 | 1.72E-04 | -3.25E-01 |
ODP kg CFC-11 eq | 8.97E-06 | 5.11E-07 | 6.82E-08 | -2.75E-06 |
AP mol H+ eq | 5.39E+00 | 5.80E-02 | 1.39E-03 | -4.75E-01 |
EP - fresh water kg P eq | 4.34E-01 | 4.04E-03 | 4.47E-05 | -4.02E-02 |
EP - marine kg P eq | 4.03E-01 | 1.54E-02 | 4.71E-04 | -4.44E-02 |
EP - country mol N eq | 4.18E+00 | 8.16E-02 | 4.94E-03 | -5.06E-01 |
POCP kg NMVOC | 1.07E+00 | 1.96E-02 | 1.19E-03 | -1.50E-01 |
ADPE kg Sb eq | 1.26E-01 | 8.65E-04 | 1.09E-06 | -7.63E-03 |
ADPF MJ | 1.71E+03 | 1.75E+02 | 3.44E+00 | -4.90E+02 |
WDP m³ depriv. | 1.02E+02 | 1.22E+00 | 1.04E-01 | -6.91E+00 |
GWP-GHG kg CO2 eq | 1.32E+02 | 7.21E+00 | 3.31E+00 | -3.81E+01 |
PM disease inc. | 1.51E-05 | 2.24E-07 | 2.13E-08 | -2.84E-06 |
IR kBq U-235 eq | 1.75E+01 | 5.86E+00 | 2.01E-02 | -4.53E+00 |
ETP - FW CTUe | 4.36E+04 | 4.10E+02 | 1.43E+01 | -3.35E+03 |
HTP - C CTUh | 1.23E-06 | 1.27E-08 | 5.28E-10 | -2.06E-07 |
HTP - NC CTUh | 6.98E-05 | 5.41E-07 | 7.53E-09 | -5.16E-06 |
SQP - | 2.48E+03 | 8.57E+01 | 4.89E+00 | -1.91E+02 |
PERE MJ | 4.12E+02 | 3.35E+01 | 1.17E-01 | -9.89E+01 |
PERM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT MJ | 4.12E+02 | 3.35E+01 | 1.17E-01 | -9.89E+01 |
PENRE MJ | 1.71E+03 | 1.75E+02 | 3.44E+00 | -4.90E+02 |
PENRM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT MJ | 1.71E+03 | 1.75E+02 | 3.44E+00 | -4.90E+02 |
SM kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW m³ | 2.97E+00 | 7.74E-02 | 3.33E-03 | -2.44E-01 |
HWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD kg | 4.72E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR kg | 0.00E+00 | 0.00E+00 | 1.43E+01 | 0.00E+00 |
MER kg | 0.00E+00 | 0.00E+00 | 1.17E+00 | 0.00E+00 |
EE (Electrical) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Accessories
Touch Panel TP 2
Suitable for: all units with control option KaControl -MC1, -MC2
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Surface-mounted housing
Suitable for: Touch Panel TP 2
Surface-mounted housing
Suitable for: Touch Panel TP 2
room temperature sensor
Suitable for: all units with control option KaControl MC
Valve kit
Suitable for: Katherm QK, Katherm QK Trench Technology
Valve body
Suitable for: Katherm NK 182 (trench heights 150 mm and 200 mm), Katherm NK 232/300/380 (all trench heights), Katherm QK, DN 15
Pre-setting key
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Return shut-off valve
Suitable for: Katherm NK, Katherm QK or Katherm HK
Differential pressure-independent valve kit
Suitable for: DN 15
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Installation cover
price per m
Suitable for: Katherm QK