• United Kingdom English (United Kingdom)
  • Projects

Country and language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Magazine
  • Contact
        • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Katherm HK
            • Katherm QK
            • Katherm QK nano
            • Katherm NK
            • Katherm QL
            • Katherm QE
          • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • TIP
            • TOP
            • Ultra
            • Ultra Allround
            • TOP C
          • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Venkon
            • KaCool D AF
            • KaDius
            • KaDeck
            • PowerKon LT
            • Venkon XL
            • KaCool W
            • KaCool D HY
          • Heat pump radiatorsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Powerkon LT
          • Perimeter Heating
          • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • WZA
          • Air curtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • UniLine
            • Cassette UniLine
            • Tandem
            • Tandem - Cassette Version
            • ProtecTor
          • Design GrillesArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Optiline
            • Wooden grilles
        • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Download Center
          • Calculation programs
        • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Customer Service
          • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Site Survey and Installation
          • SeminarsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • CPD Inhouse Seminars
            • CPD Webinars
        • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • The Kampmann UK Ltd.
          • Research and development
          • Sustainability
          • Compliance
        • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
          • News
          • Technology and knowledge
        • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Find Contact
          • Contact Form
        • Home
        • Products
        • Fan coils
        • KaCool D HY
        • Calculation

        Products

        • Trench Technology
        • Unit Heaters
        • Fan Coils
        • Heat pump radiators
        • Air curtains
        • Perimeter Heating
        • Decentralised Ventilation Units
        • Design Grilles

        Company

        • The Kampmann UK Ltd.
        • Research and Development
        • Sustainablility
        • Magazine

        Support

        • Project Support
        • Customer Service
        • Contact
        • Seminars

        Contact

        +44 1932 228592info@kampmann.co.uk
        • Imprint
        • General Terms and Conditions
        • Central Data Protection Instructions
        • Cookies
        • Reporting system
        • Modern Slavery Statement
        • Compliance

        Our products are intended exclusively for B2B sales.

        KaCool D HY

        Ceiling cassette for heating, cooling and filtering. Hygiene-certified according to VDI 6022.

        • Heating
        • Cooling
        Product image
        Hero image
        • Overview
        • Variants
        • Calculation & selection
        • Planning information
        • Downloads

        Installation distances and heights

        • Mounting height max. 3.5 m
        • Wall distance min. 1.4 m
        • Device distance min. 4 m
        • If possible, stagger the units
        • Utilization of the Coanda effect through horizontal air distribution for a high throw
        • Slow and comfortable lowering of the conditioned air into the room

        Avoid the following:

        • Impairment of free air circulation due to e.g. lamps, furniture or shelves
        • Obstruction of air intake and air distribution
        • Electronic units below the unit
        • Inaccessibility for maintenance work

        Inspection hatches

        • When installing in closed ceilings, service hatches must be taken into account.
        • No additional service hatches need to be taken into account when installing in system ceilings.
        • Further information on the service hatches in the installation instructions.

        condensate drain

        When operating the unit below the dew point, note the following:

        • The maximum delivery height of the condensate pump is 600 m from the lower edge of the unit and must not be exceeded.
        • Condensate lines must be ventilated or vented. Provide lines with a permanent and continuous gradient (1%). Avoid inclines or so-called "water pockets". Use only fixed lines (no flexible hoses) for horizontal lines.
        • Connections and transitions (e.g. from hose to fixed line) must be tightly and mechanically secured, e.g. by the use of hose clamps.
        • If a siphon stop device is located at the transition point from the device to the on-site drain, it must be mounted at the highest point of the drainage profile.
        • Protect condensate-carrying lines against falling below the dew point, e.g. by means of vapour diffusion-tight insulation.

        Hygiene compliance

        • Complies with the relevant hygiene guideline VDI 6022
        • Goal: Ensuring hygienic supply air that is harmless to health
        • Applies to common rooms such as workplaces, meeting rooms, break rooms, living rooms, sports facilities and sales rooms.
        • With factory-fitted ISO Coarse filter in the intake area.
        • Accessibility of all ventilated and water-bearing components for cleaning.

        Clean air

        • Heating and cooling for rooms with special hygiene requirements
        • VDI 6022-certified ceiling cassette for hygienic operation and maintenance
        • Utilization of the Coanda effect for maximum comfort in occupied rooms
        • Different requirements, different filters: both ePM10 >50% (M5) and ePM1 >50% (F7) available

        design trim

        • Diffuser optimized for maximum comfort through lateral air discharge and exploitation of the Coanda effect
        • Enables easy access to maintenance components

        hygiene

        • Hygienically compliant according to VDI 6022
        • Certified by the HyBeta hygiene institute

        Heat exchanger

        • High-performance copper-aluminum heat exchanger
        • with high heating and cooling output
        • flow-optimized

        Radial fan

        • Stepless EC alternating current radial fan
        • High efficiency thanks to the use of efficient EC technology

        motor protection class IP 54

        • Compact design thanks to external rotor motor technology
        • Quiet operation due to optimized air flow

        Valves

        • Various valve kits available: 2-way, 3-way and differential pressure independent valves combined with corrugated pipes and actuators

        Hydraulic connections

        • for PKW, PWW and condensate drainage
        • Drip tray included with the unit

        Model size

        The units are available in several model sizes to allow the performance to be tailored to requirements. The model size is selected depending on the required thermal output, the air volume flow and the sound requirements of the room. Larger model sizes offer higher performance, but are associated with larger housing dimensions, which must be taken into account when planning the installation situation.

        Model sizePanel (A)Width (B)Height (C)
        1600 mm575 mm385 mm
        2600 mm575 mm385 mm
        3600 mm575 mm385 mm
        4600 mm575 mm385 mm

        System

        2-pipe system

        With this design, the entire heat exchanger surface is available for temperature control, depending on the medium currently present in the pipe system (cold or hot water). Switch-over between heating and cooling takes place centrally via the building management system. This variant is particularly suitable for applications with seasonal switch-over and reduced installation effort.

        4-pipe system

        This version is suitable for sophisticated air conditioning concepts in which each room zone or unit can be switched over individually between heating and cooling. By routing the heating and cooling medium separately, the system offers maximum flexibility and comfort - ideal for buildings with changing usage requirements.

        Type of system
        2-pipe
        4-pipe

        Filter class

        Different filter types are available depending on the application area and the air quality requirements.

        The standard version with an ISO Coarse filter primarily serves to protect the device by retaining coarse particles such as dust and fibers.

        For applications with increased demands on indoor air quality, more powerful filters in accordance with ISO ePM, MERV or HEPA can be integrated as an option. These improve the indoor air by removing fine particles and aerosols from the intake air.

        The suitable filter should be selected taking into account the project-specific requirements and the planned maintenance intervals.

        Filter class
        Filter ePM1>50% (F7)
        Filter ePM10>50% (M5)

        Control option

        We offer various solutions for the control and regulation of our units, which can be used depending on the application and requirements:

        Electromechanical control

        This variant is ideal for simple applications. All integrated actuators are factory-wired to terminals and can be connected to our electromechanical accessories such as thermostats or external controllers.

        KaControl MC1

        Our comprehensive comfort control offers extended control options for individual rooms or appliance groups. It can be operated either via a touch display or a web interface. Thanks to on-site 0-10 V control or common communication protocols such as Modbus RTU & TCP, BACnet and KNX, this solution is ideal for all BMS applications.

        Control option
        electromechanical
        KaControl MC1

        Results per page

          Results per page

          Page 1 of 0

          Results per page

            Results per page

            Page 1 of 0