• United Kingdom English (United Kingdom)
  • Projects

Country and language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Magazine
  • Contact
        • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Katherm HK
            • Katherm QK
            • Katherm QK nano
            • Katherm NK
            • Katherm QL
            • Katherm QE
          • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • TIP
            • TOP
            • Ultra
            • Ultra Allround
            • TOP C
          • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Venkon
            • KaCool D AF
            • KaDius
            • KaDeck
            • PowerKon LT
            • Venkon XL
            • KaCool W
            • KaCool D HY
          • Heat pump radiatorsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Powerkon LT
          • Perimeter Heating
          • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • WZA
          • Air curtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • UniLine
            • Cassette UniLine
            • Tandem
            • Tandem - Cassette Version
            • ProtecTor
          • Design GrillesArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Optiline
            • Wooden grilles
        • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Download Center
          • Calculation programs
        • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Customer Service
          • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Site Survey and Installation
          • SeminarsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • CPD Inhouse Seminars
            • CPD Webinars
        • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • The Kampmann UK Ltd.
          • Research and development
          • Sustainability
          • Compliance
        • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
          • News
          • Technology and knowledge
        • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Find Contact
          • Contact Form
        • Home
        • Products
        • Perimeter Heating
        • Calculation

        Products

        • Trench Technology
        • Unit Heaters
        • Fan Coils
        • Heat pump radiators
        • Air curtains
        • Perimeter Heating
        • Decentralised Ventilation Units
        • Design Grilles

        Company

        • The Kampmann UK Ltd.
        • Research and Development
        • Sustainablility
        • Magazine

        Support

        • Project Support
        • Customer Service
        • Contact
        • Seminars

        Contact

        +44 1932 228592info@kampmann.co.uk
        • Imprint
        • General Terms and Conditions
        • Central Data Protection Instructions
        • Cookies
        • Reporting system
        • Modern Slavery Statement
        • Compliance

        Our products are intended exclusively for B2B sales.

        PowerKon QE

        Free-standing convector with electric heating coil and tangential fan-assisted convection.

        • Heating
        • Overview
        • Variants
        • Calculation & selection
        • Planning information
        • Downloads

        EC tangential fan

        • with integrated protective grille as contact protection for uniform air flow through the heating coil
        • resulting in high heat output with low noise emissions
        • Stepless speed control via an external 0-10 V signal Motor monitoring with integrated fault processing

        Grille fixing

        • As contact protection, factory-fitted
        • Grate can only be removed with tools

        Electric heating element wiring

        • made of stainless steel/aluminum-zinc with stepless power control
        • Heating coil and fan controlled via a 0-10 V signal

        Cover plate

        • as visual protection for the connections
        • with integrated ventilation slots

        Connection area

        • Protection class IP 65
        • Connection of the heating coil to the power control system at the factory
        • with bottom-side connection opening for electrical connection

        Height, depth & length

        Freestanding convectors can be selected in various lengths (A) so that they can be optimally integrated into common window hinge systems.

        The functional installation depth (B) and height (C) allow individual adaptation to the installation location and at the same time determine the performance of the convectors.

        Height (C)Depth (B)Length (A)
        200 mm205 mm825 mm
        200 mm205 mm1250 mm
        200 mm205 mm1700 mm

        Grille finish

        Various roller grating variants are available for the cover, which ideally fulfill both functional and design requirements. Different materials can be selected depending on the application area.

        In addition, different surface coatings and colors are possible in order to achieve a visual adaptation to the building architecture and interior design.

        What is technically relevant is that the choice of material and geometry can influence the free air cross-section and thus have an impact on the performance of the unit. These effects are taken into account in the performance calculation.

        Grille designGrille finishGrille bar spacingFree area, approx.
        Roll-up grilleAluminium, natural anodised9.0 mm65 %
        Roll-up grilleAluminium, brass anodised9.0 mm65 %
        Roll-up grilleAluminium, bronze anodised9.0 mm65 %
        Roll-up grilleAluminium, black anodised9.0 mm65 %
        Roll-up grilleAluminium, light bronze9.0 mm65 %
        Roll-up grilleAluminium, painted DB 7039.0 mm65 %
        Roll-up grilleStainless steel9.0 mm65 %
        Roll-up grilleStainless steel, polished 9.0 mm65 %
        Roll-up grilleBrass, natural9.0 mm65 %

        Heat outputs and safety functions

        The heat output and safety functions were determined in accordance with BS EN 60335, Part 1, Part 2 - 30 and Part 2 - 40.

        BS EN 60335 regulates, among other things, the operating and functional behavior of:

        • improper operation, e.g. covering the grate;
        • overvoltages occurring in the grid;
        • maximum surface temperatures, e.g. on the grate surface;
        • Function of the safety devices;
        • Moisture resistance.

        Arrangement of air outlet for cooling / heating

        • Arrangement of heating coils on the window side, tangential fan on the room side
        • Effective heating and cold air screening for glass surfaces
        • The rising air forms an air roll that ventilates draught-free into the room.

        Acoustics

        The units are equipped with quiet, sound-optimized EC fans.

        Sound pressure and sound power levels are tabulated in the technical data.

        The actual sound pressure level depends heavily on:

        • the number of units;
        • the acoustic properties of the room.

        Recommendation: The design should always take into account the permissible sound pressure level in the room.

        Control

        Two control concepts are available for controlling the PowerKon QE:

        • Control by a room temperature controller
        • Control by an external BMS

        In both concepts, the EC tangential fans are speed-controlled via a 0-10 V signal.

        As soon as the EC tangential fans are switched on at any setpoint, the stepless heating output control goes into operation.

        The right electric heat output is provided for every volumetric flow.

        Results per page

          Results per page

          Page 1 of 0

          Results per page

            Results per page

            Page 1 of 0