• United Kingdom English (United Kingdom)
  • Projects

Country and language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Magazine
  • Contact
      • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Katherm HK
          • Katherm QK
          • Katherm QK nano
          • Katherm NK
          • Katherm QL
          • Katherm QE
        • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
          • TIP
          • TOP
          • Ultra
          • Ultra Allround
          • TOP C
        • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Venkon
          • KaCool D AF
          • KaDius
          • KaDeck
          • PowerKon LT
          • Venkon XL
          • KaCool W
          • KaCool D HY
        • Heat pump radiatorsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Powerkon LT
        • Perimeter HeatingArrow Right 1 Streamline Icon: https://streamlinehq.com
          • PowerKon + F
          • PowerKon + W
          • PowerKon + ST
          • PowerKon nano
          • PowerKon QE
        • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • WZA
        • Air curtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • UniLine
          • Cassette UniLine
          • Tandem
          • Tandem - Cassette Version
          • ProtecTor
        • Design GrillesArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Optiline
          • Wooden grilles
      • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Download Center
        • Calculation programs
        • Air Volume Flow Calculator
      • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Customer Service
        • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Site Survey and Installation
        • SeminarsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • CPD Inhouse Seminars
          • CPD Webinars
      • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
        • The Kampmann UK Ltd.
        • Research and development
        • Sustainability
        • Compliance
      • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
        • News
        • Technology and knowledge
      • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Find Contact
        • Contact Form
      • Home
      • Products
      • Trench Technology
      • Katherm Hk

      Products

      • Trench Technology
      • Unit Heaters
      • Fan Coils
      • Heat pump radiators
      • Air curtains
      • Perimeter Heating
      • Decentralised Ventilation Units
      • Design Grilles

      Company

      • The Kampmann UK Ltd.
      • Research and Development
      • Sustainablility
      • Magazine

      Support

      • Project Support
      • Customer Service
      • Contact
      • Seminars

      Contact

      +44 1932 228592info@kampmann.co.uk
      • Imprint
      • General Terms and Conditions
      • Central Data Protection Instructions
      • Cookies
      • Reporting system
      • Modern Slavery Statement
      • Compliance

      Our products are intended exclusively for B2B sales.

      Katherm HK

      Article no.: 143322313113C1
      • Details
      • Description
      • Technical data
      • Acoustic data
      • EPD
      • Dimensions
      • Accessories
      • BIM
      • Downloads

      basic unit

      Kampmann Katherm HK trench heater, ready-to-install floor trench, either for installation in raised or screeded floors, convector-based for heating and cooling with tangential fan convection. Heat and cooling outputs tested in accordance with E DIN EN 16430, parts 1 to 3. Hygiene-certified in line with VDI 6022.
      Trench chassis made of sendzimir galvanised sheet steel, coated in graphite gray on both sides. Height-adjustable on the sides using mounting aids, with impact sound insulation; features a sturdy height-adjustment mechanism with impact sound insulation, for secure mounting of the duct. With pre-punched openings for water supply and return as well as electrical connections, on the room side.
      Trench chassis prepared for condensate pump mounting kit. Segmented sheets serving as both finger protection for the tangential fan and a mounting frame for the filter fleece, air-guidance sheet, grate support, and cross-brace for reinforcing the duct. Center wall serving as both an air-guidance sheet and a mounting plate for the tangential fan.
      Life Cycle Assessment (LCA) data is published in the form of an EPD according to EN 15804 and is available to download from the International EPD System. Registered in the building products platform DGNB Navigator. GWP (phase A1-A3), kg CO2 Äq.7,06E+01. Further calculations possible online.

      Heat exchanger

      High-performance heat exchanger made of circular copper pipes with aluminum fins and a Eurokonus valve connection, coated in graphite gray. Features an anti-rotation device. Collector with integral bleed option.
      System2-pipe
      Max. operating pressurebar10
      Max. entering water temperature°C95
      Min. entering water temperature°C5
      Max. air inlet temp.°C40
      Max. glycol volume%50

      Condensate tray

      Condensate tray has a flow-optimised design, for the simultaneous discharge of condensate and air guidance below the convector. Condensate tray designed as an independent component that can be removed for cleaning and maintenance in accordance with VDI 6022.

      Fan

      Tangential fan with safety guard. Energy-saving EC fan with 0-10 V input for continuously variable speed control with sound-optimised commutation electronics. Valve controlled via 24 V DC control contacts. All rotating parts have low-noise and maintenance-free bearings. Motor monitoring with internal fault processing.
      Uniform airflow through the convector, low power consumption for efficient, energy-saving operation, and optimized for low noise levels. Easily removable for cleaning and Maintenance thanks to a combined coupling/ball-bolt system that also provides acoustic decoupling. Factory-wired and ready for connection.

      Control

      KaControl smart board control version, electrical connection unit factory-fitted and wired in the unit. Operation via a separate room control unit acting as a master unit or used as a slave unit in group mode, alternatively single unit control via an analogue 0-10 V signal, alternatively single unit control via communication cards.
      KaControl control board functions:
      • room control of up to six units via a KaControl t-LAN interface
      • room control of up to 30 units and CANbus card additionally required
      • Temperature measurement optionally via sensor in the room control unit or external room temperature sensor
      • Slot for communication cards (KNX TP, Modbus RTU)
      • two digital inputs, parametrisable
      • condensate alarm
      • Device On/Off
      • Comfort/Economy switch-over with invertible switching logic
      • Three multifunction inputs, e.g. for room temperature or air intake sensors.
      • Two digital outputs for control of 1 heating valve / 1 cooling valve 24 V DC
      • error message 24 V DC, only with 2-pipe
      • optional fan activation via contact sensor opt.
      • room and unit frost protection control
      • offset function for temperature sensor
      • Demand-led or manual fan control (0-100%)
      • parameter-driven integration of natural convection into the control sequence
      • Sequential control of valve and fan via a 0-10 VDC point. Motor monitoring with fault signal processing on the KaControl control board factory-wired ready for connection.

      Grille

      With frame insert profile, colour-coordinated to the grille. With protective installation cover and frame trim. With cover panels for connection areas. With double T-profile grille. Connections made of corrosion-proof steel springs with matching spacers.

      Configuration

      Grille designRoll-up grille
      Grille finishStainless steel
      ConnectionEurocone, single-sided, heating/cooling connection side on the left
      Lengthmm915
      Widthmm320
      Heightmm130
      Bar heightmm18
      Bar depthmm6
      Bar spacingmm10
      Free area, approx. %65
      Weightkg20.2

      EC tangential fan

      • with powerful, noise-optimized EC fan motor
      • as a continuous fan belt with flow-optimized cross-flow rollers, cascaded by an innovative coupling system
      • Continuous, even flow through the convectors
      • Stepless speed control via 0-10 V signal, motor monitoring with internal fault processing

      Attachment of cross-flow fan

      • Easy removal of the tangential fan without tools
      • Innovative combined coupling/ball stud system
      • Simultaneous sound decoupling

      KaControl smart room control

      • KaControl control system for operation via separate room control unit, external control via 0-10V signal or via building automation systems such as KNX, Modbus, BACnet (additional accessories plug-in card required)
      • Room group control of up to six units or up to 30 units via additionally required CanBus cards
      • Demand-dependent automatic fan control or optional manual fan control
      • Connection options e.g. external room sensor, window contact etc.
      • Individually parameterizable for optimum adaptation to the conditions on site

      KaControl control option with external 0-10 V control

      The KaControl control option provides the option of omitting the valve control data point when externally controlled by an on-site 0-10 V signal. The fan valve and speed control logic comes from the KaControl. Note the deviation of the signal points from the design program with 0-10 V control by others.

      Design program data: 2 V 4 V 6 V 8 V 10 V

      External 0-10 V on the KaControl: 4.3 V 5.5 V 6.8 V 7.8 V 10 V

      Segment plate

      • As simultaneous finger protection for the tangential fan, filter mounting frame, air guide plate, grate support and cross brace for stiffening the duct

      Control terminal box

      • for a quick and safe electrical connection, saves installation time
      • KaControl MC or electromechanical control

      Cover plate

      • as a privacy screen and protection against soiling
      • for connection/deflection and intermediate areas

      Connection kit for condensation pump

      • As accessories, for draining the condensate if necessary
      • provided or factory-fitted
      • Electrical connection on site

      View

      • IFront view
      • IItop view (without cover panel)
      • IIIcross-section

      Further Information

      • 1window side
      • 2room side

      Specifications

      Length (A)915 mm
      finned length (B)375 mm
      Weight20.2 kg

      We consider the environmental impact of our products throughout their entire life cycle! The result is Environmental Product Declarations (EPDs). The EPDs can be easily submitted to all common building sustainability certification systems, such as DGNB, BREEAM, or LEED, and are available in the download area or directly here via the download button. In addition, the product is registered on the DGNB Navigator building products platform.

      Basic data

      Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
      GWP - Total
      Climate change - total
      kg CO2 eq6.84E+011.53E+006.73E-017.06E+012.25E+002.73E-011.32E-013.51E-026.37E-014.44E+000.00E+007.65E-022.57E+003.82E-02-3.09E+01
      GWP - fossil
      Climate change - fossil
      kg CO2 eq6.82E+011.52E+002.44E+007.22E+012.24E+002.70E-011.23E-013.08E-026.29E-013.90E+000.00E+007.65E-022.57E+003.82E-02-3.06E+01
      GWP - Biogenic
      Climate change - biogenic
      kg CO2 eq-1.30E-013.19E-03-1.77E+00-1.90E+003.19E-032.12E-035.31E-03-3.19E-035.31E-035.40E-010.00E+001.85E-044.89E-043.82E-04-1.49E-02
      GWP - Luluc
      Climate change - land use and land use change
      kg CO2 eq3.21E-011.06E-034.25E-033.26E-013.63E-042.70E-042.12E-037.44E-033.19E-035.31E-030.00E+002.87E-056.46E-053.83E-05-2.22E-01
      ODP
      Ozone Depletion
      kg CFC-11 eq3.15E-063.79E-071.27E-073.65E-065.23E-071.16E-081.05E-082.92E-093.79E-082.65E-070.00E+001.91E-082.21E-081.16E-08-2.06E-06
      AP
      Acidification
      mol H+ eq7.58E-015.31E-035.31E-037.69E-011.17E-021.06E-035.06E-042.35E-042.55E-021.17E-020.00E+002.44E-045.29E-043.20E-04-4.48E-01
      EP - Freshwater
      Eutrophication aquatic freshwater
      kg P eq6.19E-029.87E-053.19E-036.52E-026.79E-058.15E-052.54E-051.06E-052.12E-031.06E-030.00E+004.97E-061.86E-051.10E-05-3.72E-02
      EP - Marine
      Eutrophication aquatic marine
      kg P eq7.95E-021.06E-032.12E-038.27E-024.25E-033.05E-041.33E-045.21E-051.06E-033.19E-030.00E+005.46E-052.05E-041.10E-04-3.82E-02
      EP - Terrestrial
      Eutrophication terrestrial
      mol N eq8.94E-011.27E-021.38E-029.21E-014.14E-022.12E-031.06E-033.46E-041.91E-023.19E-020.00E+001.06E-032.12E-031.06E-03-4.44E-01
      POCP
      Photochemical ozone formation
      kg NMVOC2.67E-013.19E-033.19E-032.74E-011.06E-021.06E-032.63E-041.08E-045.31E-037.44E-030.00E+001.52E-044.85E-042.95E-04-1.29E-01
      ADPE
      Depletion of abiotic resources - minerals and metals
      kg Sb eq1.12E-023.63E-064.43E-061.12E-022.15E-061.66E-068.05E-075.16E-071.06E-031.10E-050.00E+001.83E-075.26E-071.24E-07-8.50E-03
      ADPF
      Abiotic resource depletion - fossil fuels
      MJ8.35E+022.48E+013.53E+018.96E+023.29E+015.80E+002.94E+004.06E-018.48E+001.04E+020.00E+001.24E+006.02E-018.90E-01-3.77E+02
      WDP
      Water use
      m³ depriv.2.09E+018.29E-021.01E-012.10E+015.42E-023.48E-013.82E-021.81E-025.51E-011.39E-010.00E+004.25E-034.14E-023.82E-02-6.63E+00
      GWP-GHG
      Global Warming Potential total excl. biogenic carbon following IPCC AR5 methodology
      kg CO2 eq6.70E+011.51E+002.44E+007.10E+012.23E+002.63E-011.22E-013.72E-026.18E-013.87E+000.00E+007.65E-022.57E+003.72E-02-2.97E+01
      PM
      Particulate Matter emissions
      disease inc.5.47E-061.33E-074.16E-085.64E-067.44E-081.83E-083.42E-092.20E-097.58E-085.51E-080.00E+006.71E-093.72E-096.20E-09-2.33E-06
      IR
      Ionizing radiation, human health
      kBq U-235 eq7.05E+001.25E-013.86E-017.56E+001.54E-011.91E-028.82E-021.06E-038.18E-023.65E+000.00E+006.37E-035.31E-034.25E-03-3.26E+00
      ETP - FW
      Ecotoxicity (fresh water)
      CTUe4.62E+031.93E+011.83E+014.66E+032.04E+016.30E+002.42E+001.05E+002.03E+024.84E+010.00E+009.73E-019.59E+006.34E-01-3.28E+03
      HTP - C
      Human toxicity, cancer effects
      CTUh4.33E-075.30E-105.35E-104.34E-073.85E-102.76E-095.40E-115.35E-117.82E-099.79E-100.00E+002.66E-113.01E-102.73E-11-1.74E-07
      HTP - NC
      Human toxicity, non-cancer effects
      CTUh7.49E-062.02E-081.71E-087.52E-062.88E-081.37E-081.52E-091.21E-093.39E-072.79E-080.00E+001.02E-094.25E-094.23E-10-5.12E-06
      SQP
      Land use related impacts/Soil quality
      -4.55E+022.92E+011.31E+026.14E+021.59E+017.37E-011.36E+006.20E-011.01E+013.92E+010.00E+001.48E+002.06E-012.21E+00-1.80E+02

      Resource use

      Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
      PERE
      Use of renewable primary energy excluding resources used as raw materials
      MJ1.89E+023.14E-012.75E+012.17E+022.22E-012.02E-016.25E-019.77E-021.84E+001.89E+010.00E+001.59E-025.84E-021.49E-02-7.22E+01
      PERM
      Use of renewable primary energy resources used as raw materials
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      PERT
      Total use of renewable primary energy
      MJ1.89E+023.14E-012.75E+012.17E+022.22E-012.02E-016.25E-019.77E-021.84E+001.89E+010.00E+001.59E-025.84E-021.49E-02-7.22E+01
      PENRE
      Use of non-renewable primary energy excluding resources used as raw materials
      MJ8.35E+022.48E+013.53E+018.96E+023.29E+015.80E+002.94E+004.14E-018.48E+001.04E+020.00E+001.24E+006.02E-018.90E-01-3.77E+02
      PENRM
      Use of non-renewable primary energy resources used as raw materials
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      PENRT
      Total use of non-renewable primary energy
      MJ8.35E+022.48E+013.53E+018.96E+023.29E+015.80E+002.94E+004.14E-018.48E+001.04E+020.00E+001.24E+006.02E-018.90E-01-3.77E+02
      SM
      Secondary material
      kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      RSF
      Renewable secondary fuels
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      NRSF
      Non-renewable secondary fuels
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      FW
      Net use of fresh water
      m³4.19E-015.31E-031.17E-024.36E-014.25E-036.37E-032.12E-030.00E+001.91E-022.55E-020.00E+002.55E-042.12E-031.06E-03-2.09E-01

      Waste & Output Flows

      Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
      HWD
      Hazardous waste disposed
      kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      NHWD
      Non-hazardous waste disposed
      kg0.00E+000.00E+003.75E+003.75E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      RWD
      Radioactive waste disposed
      kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      CRU
      Components for reuse
      kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      MFR
      Material for recycling
      kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+001.14E+010.00E+000.00E+00
      MER
      Materials for energy recovery
      kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+008.97E-010.00E+000.00E+00
      EE (Electrical)
      Exported energy electrical
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      EE (Thermal)
      Exported energy thermal
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00