• United Kingdom English (United Kingdom)
  • Projects

Country and language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Magazine
  • Contact
        • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Katherm HK
            • Katherm QK
            • Katherm QK nano
            • Katherm NK
            • Katherm QL
            • Katherm QE
          • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • TIP
            • TOP
            • Ultra
            • Ultra Allround
            • TOP C
          • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Venkon
            • KaCool D AF
            • KaDius
            • KaDeck
            • PowerKon LT
            • Venkon XL
            • KaCool W
            • KaCool D HY
          • Heat pump radiatorsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Powerkon LT
          • Perimeter Heating
          • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • WZA
          • Air curtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • UniLine
            • Cassette UniLine
            • Tandem
            • Tandem - Cassette Version
            • ProtecTor
          • Design GrillesArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Optiline
            • Wooden grilles
        • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Download Center
          • Calculation programs
        • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Customer Service
          • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Site Survey and Installation
          • SeminarsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • CPD Inhouse Seminars
            • CPD Webinars
        • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • The Kampmann UK Ltd.
          • Research and development
          • Sustainability
          • Compliance
        • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
          • News
          • Technology and knowledge
        • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Find Contact
          • Contact Form
        • Home
        • Products
        • Trench Technology
        • Katherm QE
        • Calculation

        Products

        • Trench Technology
        • Unit Heaters
        • Fan Coils
        • Heat pump radiators
        • Air curtains
        • Perimeter Heating
        • Decentralised Ventilation Units
        • Design Grilles

        Company

        • The Kampmann UK Ltd.
        • Research and Development
        • Sustainablility
        • Magazine

        Support

        • Project Support
        • Customer Service
        • Contact
        • Seminars

        Contact

        +44 1932 228592info@kampmann.co.uk
        • Imprint
        • General Terms and Conditions
        • Central Data Protection Instructions
        • Cookies
        • Reporting system
        • Modern Slavery Statement
        • Compliance

        Our products are intended exclusively for B2B sales.

        Katherm QE

        Fan-assisted trench heating with EC technology and electrical element.

        • Heating
        Product image
        Hero image
        • Overview
        • Variants
        • Calculation & selection
        • Planning information
        • Downloads

        Roller grille fixing

        • Fitted at the factory as contact protection
        • Roll-up grille can only be removed with tools

        EC tangential fan

        • with integrated protective grille as contact protection
        • for uniform air flow through the heating coil; thus high heat output with low noise emissions
        • Robust motor design
        • Stepless speed control via an external 0-10 V signal
        • Motor monitoring with integrated fault processing

        Electric heating element wiring

        • made of stainless steel tubes with aluminum-zinc fins
        • with factory-fitted safety protection tube for 2-stage safety chain consisting of safety thermostat and temperature safety device

        Connection for electric heating element

        • Protection class IP 65
        • Connection of the heating coil to the power control system at the factory

        Cover plate

        • as a privacy screen and protection against soiling
        • with integrated ventilation slots

        Width, height & length

        Trench convectors can be selected in different lengths (A) depending on the version, so that they can be optimally integrated into common window hinge systems.

        The functional width (B) and height (C) allow individual adaptation to the floor structure and at the same time determine the performance of the trench convectors.

        Continuous hinges can be realized using empty parts, column recesses, angles, etc.

        Width (B)Height (C)Length (A)
        207 mm112 mm825 - 1700 mm

        Grate start / Grate design

        Various grating variants are available for the cover, which ideally meet both functional and design requirements. Different materials can be selected depending on the application area.

        In addition, different surface coatings and colors are possible in order to achieve a visual adaptation to the building architecture and interior design.

        What is technically relevant is that the choice of material and geometry can influence the free air cross-section and thus have an impact on the performance of the unit. These effects are taken into account in the performance calculation.

        Grille designGrille finishGrille bar spacingFree area, approx.
        Roll-up grilleAluminium, natural anodised9.0 mm65 %
        Roll-up grilleAluminium, brass anodised9.0 mm65 %
        Roll-up grilleAluminium, bronze anodised9.0 mm65 %
        Roll-up grilleAluminium, black anodised9.0 mm65 %
        Roll-up grilleAluminium, light bronze9.0 mm65 %
        Roll-up grilleAluminium, painted DB 7039.0 mm65 %
        Roll-up grilleStainless steel10.5 mm65 %
        Roll-up grilleStainless steel, polished 10.5 mm65 %
        Roll-up grilleBrass, natural9.0 mm65 %

        Heat outputs and safety functions

        The heat output and safety functions were determined in accordance with BS EN 60335, Part 1, Part 2 - 30 and Part 2 - 40.

        BS EN 60335 regulates, among other things, the operating and functional behavior of:

        • improper operation, e.g. covering the grate;
        • overvoltages occurring in the grid;
        • maximum surface temperatures, e.g. on the grate surface;
        • Function of the safety devices;
        • Moisture resistance.

        Arrangement of air outlet for cooling / heating

        • directly on the façade, without a large gap (A, B)
        • provide expansion joints (1) on site to prevent compression by, for example, screed
        • Arrangement convector on the window side, tangential fan on the room side
        • effective heating and cold air shielding for glass surfaces
        • Rising air forms an air vortex that flows into the room without creating a draft.

        Acoustics

        The units are equipped with quiet, sound-optimized EC fans.

        Sound pressure and sound power levels are tabulated in the technical data.

        The actual sound pressure level depends heavily on:

        • the number of units;
        • the acoustic properties of the room.

        Recommendation: The design should always take into account the permissible sound pressure level in the room.

        Control

        Two control concepts are available for controlling the Katherm QE:

        • Control by a room temperature controller
        • Control by an external BMS

        In both concepts, the EC tangential fans are speed-controlled via a 0-10 V signal.

        As soon as the EC tangential fans are switched on at any setpoint, the stepless heating output control goes into operation.

        The right electric heat output is provided for every volumetric flow.

        Life Cycle Assessment Data (LCA)

        • Considers the environmental impact of the product over its entire life cycle.
        • Published as an Environmental Product Declaration (EPD) in accordance with standard EN 15804.
        • Available for download at International EPD System.
        • Item number-specific life cycle assessment data in the technical data sheets.
        • Product is registered in the DGNB Navigator (building product platform).

        Serves as proof for certification systems, e.g:

        • DGNB (German Sustainable Building Council);
        • BREEAM (Building Research Establishment Environmental Assessment Method);
        • LEED (Leadership in Energy and Environmental Design).

        Results per page

          Results per page

          Page 1 of 0

          Results per page

            Results per page

            Page 1 of 0