• United Kingdom English (United Kingdom)
  • Projects

Country and language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Magazine
  • Contact
        • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Katherm HK
            • Katherm QK
            • Katherm QK nano
            • Katherm NK
            • Katherm QL
            • Katherm QE
          • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • TIP
            • TOP
            • Ultra
            • Ultra Allround
            • TOP C
          • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Venkon
            • KaCool D AF
            • KaDius
            • KaDeck
            • PowerKon LT
            • Venkon XL
            • KaCool W
            • KaCool D HY
          • Heat pump radiatorsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Powerkon LT
          • Perimeter Heating
          • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • WZA
          • Air curtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • UniLine
            • Cassette UniLine
            • Tandem
            • Tandem - Cassette Version
            • ProtecTor
          • Design GrillesArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Optiline
            • Wooden grilles
        • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Download Center
          • Calculation programs
        • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Customer Service
          • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Site Survey and Installation
          • SeminarsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • CPD Inhouse Seminars
            • CPD Webinars
        • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • The Kampmann UK Ltd.
          • Research and development
          • Sustainability
          • Compliance
        • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
          • News
          • Technology and knowledge
        • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Find Contact
          • Contact Form
        • Home
        • Products
        • Trench Technology
        • Katherm QK
        • Calculation

        Products

        • Trench Technology
        • Unit Heaters
        • Fan Coils
        • Heat pump radiators
        • Air curtains
        • Perimeter Heating
        • Decentralised Ventilation Units
        • Design Grilles

        Company

        • The Kampmann UK Ltd.
        • Research and Development
        • Sustainablility
        • Magazine

        Support

        • Project Support
        • Customer Service
        • Contact
        • Seminars

        Contact

        +44 1932 228592info@kampmann.co.uk
        • Imprint
        • General Terms and Conditions
        • Central Data Protection Instructions
        • Cookies
        • Reporting system
        • Modern Slavery Statement
        • Compliance

        Our products are intended exclusively for B2B sales.

        Katherm QK

        EC tangential fan-assisted convection for heating.

        • Heating
        • Ventilation
        Product image
        Exploded view
        Hero image
        • Overview
        • Variants
        • Calculation & selection
        • Planning information
        • Downloads

        For higher room loads

        • For rooms with floor-to-ceiling windows
        • Fast heating with low noise level
        • for LPHW and heat pump operation
        • Simple installation and hydraulics connection
        • Continuous channel bands possible, adapted to facades
        • Ready-to-connect control systems and integration in BMS systems
        • Simple hydraulics connection via suitable valve sets
        • Primary air intake via connectable supply air ducts
        • Cover plates for privacy and protection against soiling
        • Extensive range of rolling and linear grilles with matching frames
        • Life cycle assessment data (EPD) available for building sustainability certification

        Slip joints possible

        • Detachable headpiece
        • for easy coupling of the trench convectors
        • for attaching dummy sections, miter corners, etc.

        EC fan

        • for uniform air flow through the convectors; thus high heat output with low noise emissions
        • Robust motor design
        • Stepless speed control via an external 0 - 10 V signal
        • Motor monitoring with internal fault processing

        Heat exchanger

        • Convectors made from proven copper / aluminum combination
        • Optimized for air flow and heat dissipation
        • graphite-grey coated

        Eurokonus valve connection

        • for quick connection
        • Saves assembly time

        Robust height adjustment

        • Step-stable height adjustment for safe elevation of the trench convectors
        • with plastic cap for sound decoupling

        Control terminal box

        • for a quick and safe electrical connection
        • Saves assembly time
        • Pipe and cable ducts for water and electrical connection punched into the trench chassis

        Width, height & length

        Trench convectors can be selected in different lengths (A) depending on the version, so that they can be optimally integrated into common window hinge systems.

        The functional width (B) and height (C) allow individual adaptation to the floor structure and at the same time determine the performance of the trench convectors.

        Continuous hinges can be realized using empty parts, column recesses, angles, etc.

        Width (B)Height (C)Length (A)
        190 mm112 mm1000 - 3200 mm
        215 mm112 mm1000 - 3200 mm

        Grate start / Grate design

        Various grating variants are available for the cover, which ideally meet both functional and design requirements. Different materials can be selected depending on the application area.

        In addition, different surface coatings and colors are possible in order to achieve a visual adaptation to the building architecture and interior design.

        It is technically relevant that the choice of material and geometry can influence the free air cross-section and thus have an impact on the performance of the unit. These effects are taken into account in the performance calculation.

        Grille designGrille finishGrille bar spacingFree area, approx.
        Roll-up grilleAluminium, natural anodised9.0 mm65 %
        Roll-up grilleAluminium, natural anodised12.0 mm70 %
        Roll-up grilleAluminium, brass anodised9.0 mm65 %
        Roll-up grilleAluminium, brass anodised12.0 mm70 %
        Roll-up grilleAluminium, bronze anodised9.0 mm65 %
        Roll-up grilleAluminium, bronze anodised12.0 mm70 %
        Roll-up grilleAluminium, black anodised9.0 mm65 %
        Roll-up grilleAluminium, black anodised12.0 mm70 %
        Roll-up grilleAluminium, light bronze9.0 mm65 %
        Roll-up grilleAluminium, light bronze12.0 mm70 %
        Roll-up grilleAluminium, painted DB 7039.0 mm65 %
        Roll-up grilleAluminium, painted DB 70312.0 mm70 %
        Roll-up grilleStainless steel10.5 mm65 %
        Roll-up grilleStainless steel, polished 10.5 mm65 %
        Roll-up grilleBrass, natural9.0 mm65 %
        Roll-up grilleBrass, natural12.0 mm70 %
        Linear grilleAluminium, natural anodised9.0 mm65 %
        Linear grilleAluminium, natural anodised12.0 mm70 %
        Linear grilleAluminium, brass anodised9.0 mm65 %
        Linear grilleAluminium, brass anodised12.0 mm70 %
        Linear grilleAluminium, bronze anodised9.0 mm65 %
        Linear grilleAluminium, bronze anodised12.0 mm70 %
        Linear grilleAluminium, black anodised9.0 mm65 %
        Linear grilleAluminium, black anodised12.0 mm70 %
        Linear grilleAluminium, light bronze9.0 mm65 %
        Linear grilleAluminium, light bronze12.0 mm70 %
        Linear grilleAluminium, painted DB 7039.0 mm65 %
        Linear grilleAluminium, painted DB 70312.0 mm70 %
        Linear grilleStainless steel10.5 mm65 %
        Linear grilleStainless steel, polished 10.5 mm65 %
        Linear grilleBrass, natural9.0 mm65 %
        Linear grilleBrass, natural12.0 mm70 %

        Control option

        We offer various solutions for the control and regulation of our units, which can be used depending on the application and requirements:

        Electromechanical control

        This variant is ideal for simple applications. All integrated actuators are factory-wired to terminals and can be connected to our electromechanical accessories such as thermostats or external controllers.

        KaControl MC1

        Our comprehensive comfort control offers extended control options for individual rooms or appliance groups. It can be operated either via a touch display or a web interface. Thanks to on-site 0-10 V control or common communication protocols such as Modbus RTU & TCP, BACnet and KNX, this solution is ideal for all BMS applications.

        Control option
        electromechanical 24 V
        electromechanical 230 V
        KaControl MC1

        Heat outputs

        • The heat outputs were determined in accordance with BS EN 16430 (Part 1-2) under realistic conditions on the basis of EN 442.
        • The standard regulates the performance measurements in uniform standards, especially for trench convectors.
        • Ensuring uniform comparability of different units.
        • Safety in planning and design.

        Arrangement of air outlet for cooling / heating

        • directly on the façade, without a large gap (A, B)
        • provide expansion joints (1) on site to prevent compression by, for example, screed
        • Arrangement convector on the window side, tangential fan on the room side
        • effective heating and shielding on glass surfaces to avoid condensation
        • Rising air forms an air vortex that flows into the room without creating a draft.

        Acoustics

        The units are equipped with quiet, sound-optimized EC fans.

        Sound pressure and sound power levels are tabulated in the technical data.

        The actual sound pressure level depends heavily on:

        • the number of units;
        • the acoustic properties of the room.

        Recommendation: The design should always take into account the permissible sound pressure level in the room.

        supply air trenches

        Additional supply air models (ZL) are available for the Katherm QK, enabling additional conditioned supply air to be fed into rooms.

        Features:

        • Trench length 400 mm
        • different nozzle sizes/designs are possible
        • Regulation of the air flow via built-in sliding elements
        • Low leaving air velocities, hence pleasant level of comfort.
        • Low sound development when correctly designed.
        • low investment and maintenance costs
        • No wear parts/no electrically rotating parts.

        Supply air volume flow

        The slider can be moved into different positions to set the required volumetric flow for the room on the supply air module.

        • 4 different slider positions are possible (100%, 75%, 50% and 30% open).
        • Reading the air volume flow, sound level and pressure losses from the diagrams in the technical documentation regarding comfort.
        • Intermediate values can be interpolated.

        Life Cycle Assessment Data (LCA)

        • Considers the environmental impact of the product over its entire life cycle.
        • Published as an Environmental Product Declaration (EPD) in accordance with standard EN 15804.
        • Available for download at International EPD System.
        • Item number-specific life cycle assessment data in the technical data sheets.
        • Product is registered in the DGNB Navigator (building product platform).

        Serves as proof for certification systems, e.g:

        • DGNB (German Sustainable Building Council);
        • BREEAM (Building Research Establishment Environmental Assessment Method);
        • LEED (Leadership in Energy and Environmental Design).