Katherm HK is low-noise and energy-efficient and is used for heating and cooling. It operates with tangential fans.

With Katherm HK trench technology, energy-efficient and noise-optimised heating and cooling is possible at all system temperatures, including low-temperature and heat pump operation. They are suitable for all types of buildings in which a predominantly higher cooling load occurs due to internal loads and solar radiation through large glazed façades.

Take advantage of the option of introducing primary air into the building with Katherm HK - either via supply air modules or supply air ducts. The new Katherm HK P (height 160 mm, width 310 mm) has primary air connections with air spigots or air intake via the raised floor.
Four trench widths and three width-dependent trench heights are available to choose from. Depending on the on-site requirements, 6 different product-specific lengths are available for all performance requirements in the 2-pipe and 4-pipe system.
Lengths: 915 – 3000 mm
Custom-made solutions are possible for every building architecture with individual geometries. This applies to the trench and the grille. Available examples include:

Every Katherm HK is equipped with a condensate tray that collects condensate generated in cooling mode and safely drains it from the trench. Condensate drainage is achieved by natural fall or optionally by a supplied or factory-fitted condensate pump .
Katherm HK units are used in acoustically sensitive rooms because the smooth-running tangential fans are mounted with acoustic decoupling thanks to the innovative combined coupling/ball-stud system.
For maintenance purposes, the fan can be removed or installed without tools.

Our Katherm trench technology products are carefully packed in cardboard packaging for transport. The grille edge trim profiles are protected against damage by green plastic profiles. A sustainable paper cover prevents dust and dirt from entering.


As the units are often installed in the building at an early construction stage, the grille can be replaced at the factory with a wooden installation cover for their protection for an additional charge. The grilles are then supplied separately packed.
The Katherm HK offers bidirectional communication of up to 10 units within a group/room via CAN bus with the integrated KaControl MC control. With KaControl MC, the unit can be easily integrated into common building management systems such as Modbus RTU, Modbus TCP, BACnet/IP and KNX-TP.
This variant is ideal for simple applications. All integrated actuators are factory-wired to a terminal and can be connected to our electromechanical accessories such as thermostats or external controllers.
Adapt the product to your requirements - these options are available for you to choose from.
Heating or cooling (central switch-over possible)
Simultaneous heating and cooling in different usage zones
Diverse versions in material and colour. Can be used on both sides. Shortening and extensions are also possible.

With our free calculation program, you can find the product with the right performance data for your project in just a few steps. The official technical data sheet with your individual project values as a PDF for download is then available to you.
Thanks to its well-designed construction, thorough cleaning in accordance with the requirements of the VDI 6022 hygiene guideline is easily possible. The condensate tray that can be pulled out towards the room enables complete cleaning of the tray.
We assess the environmental impact of our products across their entire life cycle („cradle to cradle“) and publish the results transparently in our Environmental Product Declarations (EPD). These EPDs can be easily integrated into leading building certification systems such as DGNB, BREEAM or LEED and are available in the download section.

Separate ventilation and temperature control with a hybrid ventilation concept: The combination of central ventilation via an air handling unit and decentralised air conditioning with pumped hot water and chilled water enables efficient heating and cooling.

Rheine
Apetito - company restaurant

Rheine
Apetito - company restaurant
Rheine

Immenstadt
Albrecht Electrical Engineering

Immenstadt
Albrecht Electrical Engineering
Immenstadt

Eislingen
Prinzing Electrical Engineering

Eislingen
Prinzing Electrical Engineering
Eislingen

Lübeck-Travemünde
SlowDown

Lübeck-Travemünde
SlowDown
Lübeck-Travemünde

Berlin
Hotel RIU Plaza

Berlin
Hotel RIU Plaza
Berlin

Riva del Garda TN, Italy
Hotel Lido Palace

Riva del Garda TN, Italy
Hotel Lido Palace
Riva del Garda TN, Italy

Barcelona
Antares Tower

Barcelona
Antares Tower
Barcelona

Bonn
UN high-rise building "Kleiner Eugen"

Bonn
UN high-rise building "Kleiner Eugen"
Bonn

Traunreut
Traunreut Municipal Utilities

Traunreut
Traunreut Municipal Utilities
Traunreut

Baden-Baden
Roomers Hotel

Baden-Baden
Roomers Hotel
Baden-Baden

Elmau-Klais
Schloss Elmau Retreat

Elmau-Klais
Schloss Elmau Retreat
Elmau-Klais

Aachen
Pulsar Photonics GmbH

Aachen
Pulsar Photonics GmbH
Aachen
We are happy to help you with the planning, calculation and selection of our products.